A quantum cascade laser infrared spectrometer for CO2 stable isotope analysis: Field implementation at a hydrocarbon contaminated site under bio-remediation.

نویسندگان

  • Christophe Guimbaud
  • Cécile Noel
  • Michel Chartier
  • Valéry Catoire
  • Michaela Blessing
  • Jean Christophe Gourry
  • Claude Robert
چکیده

Real-time methods to monitor stable isotope ratios of CO2 are needed to identify biogeochemical origins of CO2 emissions from the soil-air interface. An isotope ratio infra-red spectrometer (IRIS) has been developed to measure CO2 mixing ratio with δ(13)C isotopic signature, in addition to mixing ratios of other greenhouse gases (CH4, N2O). The original aspects of the instrument as well as its precision and accuracy for the determination of the isotopic signature δ(13)C of CO2 are discussed. A first application to biodegradation of hydrocarbons is presented, tested on a hydrocarbon contaminated site under aerobic bio-treatment. CO2 flux measurements using closed chamber method is combined with the determination of the isotopic signature δ(13)C of the CO2 emission to propose a non-intrusive method to monitor in situ biodegradation of hydrocarbons. In the contaminated area, high CO2 emissions have been measured with an isotopic signature δ(13)C suggesting that CO2 comes from petroleum hydrocarbon biodegradation. This first field implementation shows that rapid and accurate measurement of isotopic signature of CO2 emissions is particularly useful in assessing the contribution of contaminant degradation to the measured CO2 efflux and is promising as a monitoring tool for aerobic bio-treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field-based stable isotope analysis of carbon dioxide by mid-infrared laser spectroscopy for carbon capture and storage monitoring.

A newly developed isotope ratio laser spectrometer for CO2 analyses has been tested during a tracer experiment at the Ketzin pilot site (northern Germany) for CO2 storage. For the experiment, 500 tons of CO2 from a natural CO2 reservoir was injected in supercritical state into the reservoir. The carbon stable isotope value (δ(13)C) of injected CO2 was significantly different from background val...

متن کامل

Feasibility of 13CO2 eddy covariance flux measurements using pulsed quantum cascade tunable infrared laser differential absorb

Better quantification of atmosphere-ecosystem exchange of the isotopologues of CO2 could substantially improve our ability to probe underlying physiological and ecological mechanisms controlling ecosystem carbon exchange, but the ability to make long-term continuous measurements of the isotopic composition of exchange fluxes has been limited by measurement difficulties. Quantum cascade (QC) las...

متن کامل

CO2 isotope sensor using a broadband infrared source, a spectrally narrow 4.4 μm quantum cascade detector, and a Fourier spectrometer

We report a prototype CO2 gas sensor based on a simple blackbody infrared source and a spectrally narrow quantum cascade detector (QCD). The detector absorption spectrum is centered at 2260 cm−1 (4.4 μm) and has a full width at half maximum of 200 cm−1 (25 meV). It covers strong absorption bands of two spectrally overlapping CO2 isotopomers, namely the P-branch of CO2 and the R-branch of CO2. A...

متن کامل

Development of a compact quantum cascade laser spectrometer for field measurements of CO2 isotopes

We report the development of a field-deployable, pulsed quantum cascade laser spectrometer. The instrument is designed to measure the 13C/12C isotopic ratio in the CO2 released from volcanic vents. Specific CO2 and CO2 absorption lines were selected around 4.3 μm, where the P-branch of CO2 overlaps the R-branch of CO2 of the 0001–0000 vibrational transition. This particular selection makes the ...

متن کامل

Hollow waveguide quantum cascade laser spectrometer as an online microliter sensor for gas chromatography.

An optical absorption sensor for gas chromatography (GC) is presented. It consists of a quantum cascade laser along with a long piece of Hollow Waveguide for Infrared (HWIR) transmission inserted into the GC line. It measures the infrared absorption in each individual gas peak after separation by the GC column, and maintains the shapes of gas peaks after the HWIR sensor, making the gas samples ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of environmental sciences

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2016