Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures.
نویسندگان
چکیده
A computational investigation of proximal humeral fracture fixation has been conducted. Four devices were selected for the study; a locking plate, intramedullary nail (IM Nail), K-wires and a Bilboquet device. A 3D model of a humerus was created using a process of thresholding based on the grayscale values of a CT scan of an intact humerus. An idealised three part fracture was created in addition to removing a standard volume from the humeral head as a representation of bone voids that occur as a result of the injury. All finite element simulations conducted represent 90° arm abduction. Simulations were conducted to investigate the effect of filling this bone void with calcium phosphate cement for each device. The effect of constructing devices from carbon fibre polyetheretherketone (CFPEEK) was investigated. Simulations of cement reinforced devices predict greater stability for each device. The average unreinforced fracture line opening (FLO) is reduced by 48.5% for metallic devices with a lesser effect on composite devices with FLO reduced by 23.6%. Relative sliding (shear displacement) is also reduced between fracture fragments by an average of 58.34%. CFPEEK device simulations predict reduced stresses at the device-bone interface.
منابع مشابه
The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma
Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...
متن کاملOsteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results
UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...
متن کاملFixation of a Proximal Humeral Fracture Using a Novel Intramedullary Cage Construct following a Failed Conservative Treatment
A majority of proximal humeral fractures are preferably treated conservatively. However, surgical management may be beneficial in proximal humeral fractures with significant displacement or angulation. Unfortunately, the complication rates associated with current surgical procedures for fracture fixation, ORIF and IM devices, can be unacceptably high. A new technology, termed the PH Cage, addre...
متن کاملOutcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital.
Proximal humerus fractures have been a challenge to achieve stable fixation. PHILOS (Proximal Humerus internal locking system) is part of the latest generation of locking compression plates for proximal humeral fracture fixation. We aim to assess the clinical and functional outcome of proximal humeral fractures (2-part, 3-part and 4-part) treated with the PHILOS plate. We prospectively reviewed...
متن کاملPhilos plate fixation for proximal humeral fractures.
PURPOSE To evaluate the efficacy of Philos plate fixation for proximal humerus fractures. METHODS Functional outcomes of 31 men and 27 women aged 36 to 73 (mean, 61) years who underwent Philos plate fixation for proximal humeral fractures were retrospectively reviewed. Indications for surgery were 3-part (n=33) or 4-part (n=25) closed proximal humeral fractures with angulation of more than 45...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2013