Gated blood pool SPECT improves reproducibility of right and left ventricular Fourier phase analysis in radionuclide angiography.
نویسندگان
چکیده
OBJECTIVES The ventricular phase angle, a parametric method applied to Fourier phase analysis (FPA) in radionuclide ventriculography, allows the quantitative analysis of ventricular contractile synchrony. However, FPA reproducibility using gated blood pool SPECT (GBPS) has not been fully evaluated. The present study evaluates whether by using GBPS, the reproducibility of FPA could be improved over that in planar radionuclide angiography (PRNA). METHODS Forty-three subjects underwent both GBPS and PRNA, of which 10 subjects were normal controls, 25 had dilated cardiomyopathy, and 8 had various heart diseases. Interventricular contractile synchrony was measured as the absolute difference in RV and LV mean ventricular phase angle as delta(phi) (RV - LV). Intraventricular contractile synchrony was measured as the standard deviation of the mean phase angle for the RV and LV blood pools (RVSD(phi), LVSD(phi)). Two nuclear physicians processed the same phase images of GBPS to evaluate the interobserver reproducibility of the phase angles using data from the 43 study participants. Phase images acquired from PRNA were processed in the same manner. RESULTS Excellent reproducibility of delta(phi) (RV - LV) was obtained with both GBPS (Y = -3.10 + 0.89 x X; r = 0.901) and PRNA (Y = -4.51 + 0.81 x X; r = 0.834). In regard to RVSD(phi) reproducibility was not adequate with PRNA (Y = 18.56 + 0.35 x X; r = 0.424), while it was acceptable with GBPS (Y = 5.22 + 0.85 x X; r = 0.864). LVSD(phi) reproducibility was superior using both GBPS (Y = 4.15 + 0.97 x X; r = 0.965) and PRNA (Y = -0.55 + 0.98 x X; r = 0.910). CONCLUSION Our results demonstrate FPA obtained using GBPS to be highly reproducible for evaluating delta(phi) (RV - LV), RVSD(phi) and LVSD(phi), in comparison with the PRNA method. We thus consider GBPS appropriate for evaluating ventricular contractile synchrony.
منابع مشابه
[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].
UNLABELLED Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS Thirty-fiv...
متن کاملPlanar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study.
UNLABELLED Gated blood-pool SPECT (GBPS), inherently 3-dimensional (3D), has the potential to replace planar equilibrium radionuclide angiography (ERNA) for computation of left ventricular ejection fraction (LVEF), analysis of regional wall motion (RWM), and analysis of right heart function. The purpose of this study was to compare GBPS and ERNA for the assessment of ventricular function in a l...
متن کاملImpact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI
Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...
متن کاملEfficacy of the phase images in Fourier analysis using gated cardiac POOL-SPECT for determining the indication for cardiac resynchronization therapy.
BACKGROUND Although cardiac resynchronization therapy (CRT) improves quality of life and survival for patients with heart failure, exact methods to estimate the effect of cardiac asynchrony have not yet been defined. METHODS AND RESULTS Initially, to examine whether the phase analysis images in the Fourier analysis using gated cardiac pool single photon emission computed tomography (POOL-SPEC...
متن کامل[Reproducibility of measurements of left ventricular function with gated myocardial perfusion SPECT and comparison with blood pool radionuclide ventriculography].
INTRODUCTION AND OBJECTIVE This study was designed to evaluate the reproducibility of ejection fraction (EF) and ventricular volume measurements obtained with single photon emission computed tomography (gated-SPECT), and to assess the correlation between EF values obtained with this method and blood pool planar radionuclide ventriculography. PATIENTS AND METHOD A total of 55 patients were inc...