A study to evaluate and compare the efficacy of preprocedural mouthrinsing and high volume evacuator attachment alone and in combination in reducing the amount of viable aerosols produced during ultrasonic scaling procedure.

نویسندگان

  • Nihal R Devker
  • Jyoti Mohitey
  • Akshay Vibhute
  • Vivek Singh Chouhan
  • Prithviraj Chavan
  • Sachin Malagi
  • Rosemary Joseph
چکیده

BACKGROUND AND OBJECTIVES In recent years, ultrasonics has gained prime importance and is considered a valuable tool in the dentist's armamentarium. Studies have confirmed that an aerosolized bacterial contamination is produced during the use of ultrasonic scalers. AIM To evaluate and compare the efficacy of preprocedural mouthrinsing using a bis-biguanide (chlorhexidine gluconate 0.2%) and high volume evacuator attachment alone and in combination in reducing the amount of viable aerosols produced during ultrasonic scaling procedure. MATERIALS AND METHODS A total 90 subjects were assigned to group I (who rinsed with 0.2% chlorhexidine gluconate prior to scaling), group II (high volume evacuator attachment was used during ultrasonic scaling) and group III (who rinsed with 0.2% chlorhexidine gluconate prior to scaling and in whom high volume evacuator attachment was used during ultrasonic scaling). Control group consisted of subject's whose mouth was scaled using a piezoelectric ultrasonic scaler without preprocedural rinsing or high volume suction. Aerosol samples were collected using blood agar plates. The blood agar plates containing the aerosol sample were taken to the microbiology department as soon as the sampling was over and were subjected to aerobic culturing. RESULTS The values obtained showed that all the three groups were effective in reducing the mean colony forming units (CFUs). CONCLUSION The results of this study showed that preprocedural rinse and high volume suction were effective when used alone as well as together in reducing the microbial load of the aerosols produced during ultrasonic scaling. There was a significant reduction in the number of CFUs in aerosol samples obtained.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of High-volume Evacuator in Aerosol Reduction: Truth or Myth? A Clinical and Microbiological Study

Background and aims. Basic periodontal treatment aims at eliminating supra- and sub-gingival plaque and establishing conditions which will allow effective self-performed plaque control. This aim is primarily achieved with sonic and ultrasonic scalers. However, generation of bacterial aerosols during these procedures is of great concern to patients, the dentist and the dental assistant. The aim ...

متن کامل

Determination of efficacy of pre-procedural mouth rinsing in reducing aerosol contamination produced by ultrasonic scalers

The oral cavity is a unique environment which can provide an ideal medium for bacterial growth. Most of the procedures performed by dentist have the potential for creating contaminated aerosols and splatter which contains bacteria, fungi, protozoa and even blood borne viruses produced during dental operative procedures and thus promoting an increased risk of cross infection. In dentistry, the u...

متن کامل

تاثیر وسیله کاهنده آئروسل بر پراکندگی آئروسل های عفونی به هنگام جرمگیری اولتراسونیک

Statement of Problem: Ultrasonic Scaling is one of the main sources of producing infected aerosols in dentistry. These aerosols are able to spread pathogens such as microorganisms associated with tuberculosis, conjunctivitis, influenza and other respiratory diseases, herpetic and other skin diseases, ADIS and hepatitis B.Purpose: The aim of this study was to investigate the clinical effective...

متن کامل

ASSESSMENT OF THE EFFICACY OF PARA CERVICAL BLOCK IN CONJUNCTION WITH CONSCIOUS SEDATION ON PAIN CONTROL DURING OUTPATIENT HYSTEROSCOPY

Background and Objective: Hysteroscopy is considered as very important in the investigation of abnormal uterine bleeding. It is usually performed as an outpatient procedure under either local or no anesthesia. This study was designed to compare the combination of paracervical block (PCB) and conscious sedation with paracervical block or conscious sedation alone for outpatient hysteroscopy i...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2012