A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software

نویسندگان

  • Jiantao Li
  • Hao Zhang
  • Peng Yin
  • Xiuyun Su
  • Zhe Zhao
  • Jianfeng Zhou
  • Chen Li
  • Zhirui Li
  • Lihai Zhang
  • Peifu Tang
چکیده

We established a novel measurement technique to evaluate the anatomic information of nutrient artery canals using Mimics (Materialise's Interactive Medical Image Control System) software, which will provide full knowledge of nutrient artery canals to assist in the diagnosis of longitudinal fractures of tibia and choosing an optimal therapy. Here we collected Digital Imaging and Communications in Medicine (DICOM) format of 199 patients hospitalized in our hospital. All three-dimensional models of tibia in Mimics were reconstructed. In 3-matic software, we marked five points in tibia which located at intercondylar eminence, tibia tuberosity, outer ostium, inner ostium, and bottom of medial malleolus. We then recorded Z-coordinates values of the five points and performed statistical analysis. Our results indicate that foramen was found to be absent in 9 (2.3%) tibias, and 379 (95.2%) tibias had single nutrient foramen. The double foramina was observed in 10 (2.5%) tibias. The mean of tibia length was 358 ± 22 mm. The mean foraminal index was 31.8%  ± 3%. The mean distance between tibial tuberosity and foramen (TFD) is 66 ± 12 mm. Foraminal index has significant positive correlation with TFD (r = 0.721, P < 0.01). Length of nutrient artery canals has significant negative correlation with TFD (r = -0.340, P < 0.01) and has significant negative correlation with foraminal index (r = -0.541, P < 0.01).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Cardiac Artery Disease by Using the DCAD (b) Module

Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...

متن کامل

New Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators

Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...

متن کامل

Measurement of Morphological Characteristics of Raw Cane Sugar Crystals Using Digital Image Analysis

Raw cane sugar is one of the most important product in the sugar industry and is the main raw material for the white sugar production. Morphological and physical properties of this product might influence the final white sugar. For instance, the behavior during centrifugation, transport and storage is related to the characteristics of these crystals. The object of this study was to determine th...

متن کامل

In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals

Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. Wi...

متن کامل

Accuracy of an Intraoral Digital System for File Length Measurement

Introdouction: Canal length measurement is essential for proper endodontic treatment. Any error or miscalculation in working length determination, particularly in curved canals, can result in complications during or after root canal therapy. Digital radiography has enabled accurate measurement of curved canal length. In this study, we evaluated the accuracy of calibration of a complementary m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015