Cardiac MR imaging with external respirator: synchronizing cardiac and respiratory motion--feasibility study.
نویسندگان
چکیده
The feasibility of electrocardiography (ECG)-synchronized respiration with an external cuirass-type respirator in cardiac magnetic resonance (MR) imaging was evaluated. Cardiac MR imaging was performed in 10 nonsedated healthy volunteers with an ECG-triggered external respirator that was modified for use in the MR environment. Coronary MR angiograms and multiphase gradient-echo cine images were acquired with one respiratory cycle performed per cardiac cycle. The technique was feasible and in this group of volunteers resulted in equivalent image quality but shorter acquisition times than those of conventional free-breathing and breath-holding techniques.
منابع مشابه
Advanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملDNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging
Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....
متن کاملFree-breathing cardiac MR imaging: study of implications of respiratory motion--initial results.
The respiratory motion of several anatomic regions (right hemidiaphragm, left ventricle of the heart, chest wall, abdominal wall) was investigated during free breathing in 10 healthy volunteers by using multinavigator technology and real-time magnetic resonance (MR) imaging. The respiratory motion shows hysteretic effects, which are strongly subject dependent and might have some effect on the q...
متن کاملRespiratory and cardiac motion correction in dual gated PET/MR imaging
LaTIM, INSERM, UMR 1101, Brest, France Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiology
دوره 227 3 شماره
صفحات -
تاریخ انتشار 2003