Biocompatible force sensor with optical readout and dimensions of 6 nm3.
نویسندگان
چکیده
We have developed a nanoscopic force sensor with optical readout. The sensor consists of a single-stranded DNA oligomer flanked by two dyes. The DNA acts as a nonlinear spring: when the spring is stretched, the distance between the two dyes increases, resulting in reduced Förster resonance energy transfer. The sensor was calibrated between 0 and 20 pN using a combined magnetic tweezers/single-molecule fluorescence microscope. We show that it is possible to tune the sensor's force response by varying the interdye spacing and that the FRET efficiency of the sensors decreases with increasing force. We demonstrate the usefulness of these sensors by using them to measure the forces internal to a single polymer molecule, a small DNA loop. Partial conversion of the single-stranded DNA loop to a double-stranded form results in the accumulation of strain: a force of approximately 6 pN was measured in the loop upon hybridization. The sensors should allow measurement of forces internal to various materials, including programmable DNA self-assemblies, polymer meshes, and DNA-based machines.
منابع مشابه
Design and Construction of a Novel Tactile Sensor for Measuring Contact-Force, Based on Piezoelectric Effect
In this paper, design and construction of a tactile sensor for measuring contact-force is presented. Mechanism of measuring contact-force in this tactile sensor is based on impedance changing of piezoelectric crystal and voltage of different points in circuit as a result of applying force on the crystal. By considering a specific point in the circuit and recording the changes of its voltage, ma...
متن کاملFabrication and Characterization of the Fiber Optical Taper for a Surface Plasmon Resonance Sensor
For a fiber optical surface plasmon resonance (SPR) sensor a short part of its cladding should be removed to coat a thin layer of a metal. Usually this is problematic when an optical fiber with small core diameter is used. In this paper, a new method using µliter droplet of the HF acid for short fiber optical taper fabrication is reported. Using this method in a multi-mode optical fiber w...
متن کاملDesign and Construction of a Sensitive Capasitive Sensor System (RESEARCH NOTE)
Design and construction of a capacitor sensor with a precise readout system are described in this paper. A variable air-gap capacitive transducer was constructed and for signalmeasurement a successful attempt was made to exploit the capacitance changes in terms of the phase angle of the detected signal. The reported setup makes it possible to detect capacitance changes of the order of 2.5 fF in...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملMeasurement of the Casimir force with a ferrule-top sensor
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold-coated sphere and a gold-coated plate with results that are comparable to those achieved by similar atomic force microscope experiments. Thanks to the monolithic design of the force sensor (which does not require ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nano letters
دوره 5 7 شماره