Behaviour of standard gravity-fed administration sets used for intravenous infusion.

نویسندگان

  • F C Flack
  • T D Whyte
چکیده

The major factor influencing drip rate during intravenous infusion using a standard administration set is the variation in the venous pressure of the patient. Creep in the plastic material, though present, is shown to be unimportant. For steady and accurate infusion it is necessary to provide the ordinary gravity-fed administration set with some form of servo-control mechanism.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary Intravenous Set Consumption Across 3 Branded Infusion Pumps

This retrospective study of 6426 hip replacement, coronary artery bypass graft, and colectomy surgeries across 23 US hospitals found that intravenous (IV) set designs that can be interchanged for use both in gravity-fed and automated pump delivery systems are replaced less frequently than IV sets designed for use primarily by one delivery method. Semistructured interviews with nurses highlighte...

متن کامل

Evaluation of Intravenous Infusion Systems for Adenosine

Adenosine is used routinely in cardiac perfusion imaging in lieu of exercise stress to enhance coronary blood flow. Since it is a potent drug, intravenous (IV) infusion of adenosine must be carefully controlled to provide optimal pharmacologic effect and minimal adverse effects. There has been particular concern about a sudden increase in adenosine delivery at the time of radiotracer administra...

متن کامل

Variations of deop size in disposable administration sets used for intravenous infusion.

The variation of drop size with drip rate has been studied for giving sets made by two major United Kindgom manufacturers. Data are given for the variation using Sodiun Chloride Injection (BP), Sodium Chloride and dexerose Injection (BP) and blood. All sets investigated conformed to BS 2463. A table is provided to enable more accurate delivery of infusion for the three fluids examined.

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

Effects of the Soil-Foundation-Structure Interaction on the Component Demand Modifier Factor of Concrete Gravity Beams based on ASCE 41-06 Standard

The aim of the present paper is to evaluate the influence of the Soil- Foundation- Structure Interaction (SFSI) effects on the component demand modifier factor of concrete gravity beams based on ASCE 41-06 standard. To this end, the beam on the nonlinear Winkler foundation approach is employed which is a simple and efficient method. At first, four sets of 3-, 6-, 10- and 15-storey concrete mome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British medical journal

دوره 3 5928  شماره 

صفحات  -

تاریخ انتشار 1974