Accuracy of the HVAD Pump Flow Estimation Algorithm.
نویسندگان
چکیده
Controller algorithms are an important feature for assessment of ventricular assist device performance. Flow estimation is one algorithm implemented in the HeartWare continuous-flow ventricular assist device pump system. This parameter estimates flow passing through the pump and is calculated using speed, current, and hematocrit. In vitro and in vivo studies were conducted to assess the algorithm accuracy. During in vitro testing, three pumps were tested in four water-glycerol solutions at 37°C with viscosities equivalent to hematocrits of 20, 30, 40, and 50%. By using a linear regression model, a correlation coefficient of >0.94 was observed between measured and estimated flow for all conditions. In vivo studies (n = 9) were conducted in an ovine model where a reference flow probe was placed on the outflow graft and speed was adjusted from 1,800 to 4,000 revolutions per minute. During in vivo experiments, estimated pump flow (mean, minimum, and maximum) was compared with measured pump flow. The best-fit linear regression equation for the data is y = 0.96x + 0.54, r = 0.92. In addition, waveform fidelity was high (r > 0.96) in normal (i.e., nonsuction) cases where flow pulsatility was >2 L/min. The flow estimation algorithm demonstrated strong agreement with measured flow, both when analyzing average waveform magnitude and fidelity.
منابع مشابه
HVAD Waveform Analysis as a Noninvasive Marker of Pulmonary Capillary Wedge Pressure: A First Step Toward the Development of a Smart Left Ventricular Assist Device Pump.
Flow waveforms are an important feature of the HVAD left ventricular assist device (LVAD) that provides information about HVAD function and patient hemodynamics. We assessed the properties of one specific aspect of the waveform, the slope of the ventricular filling phase (VFP), and its correlation with pulmonary capillary wedge pressure (PCWP). A total of 101 screenshots from the HVAD monitor a...
متن کاملAn Advanced State Estimation Method Using Virtual Meters
- Power system state estimation is a central component in energy management systems of power system. The goal of state estimation is to determine the system status and power flow of transmission lines. This paper presents an advanced state estimation algorithm based on weighted least square (WLS) criteria by introducing virtual meters. For each bus of network, except slack bus, a virtual meter...
متن کاملImplantation of the HeartWare HVAD: from full sternotomy to less invasive techniques.
Left ventricular assist devices (LVADs) are increasingly used for the treatment of end-stage congestive heart failure, both as a bridge to transplantation and as destination therapy (1). The HeartWare HVAD (HeartWare Inc, Framingham, MA, USA) is a continuous centrifugal-flow left ventricular assist device with a magnetic levitating rotor pump. The pump weighs just 140 g and its small design all...
متن کاملNoninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.
The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a mock loop under steady flow conditions for a variety of pump operating points ...
متن کاملExperimental Study and Three-Dimensional Numerical Flow Simulation in a Centrifugal Pump when Handling Viscous Fluids
In this paper the centrifugal pump performances are tested when handling water and viscous oils as Newtonian fluids. Also, this paper shows a numerical simulation of the three-dimensional fluid flow inside a centrifugal pump. For these numerical simulations the SIMPLEC algorithm is used for solving governing equations of incompressible viscous/turbulent flows through the pump. The k-ε turbulenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ASAIO journal
دوره 62 1 شماره
صفحات -
تاریخ انتشار 2016