Detection of faults in implanted cardiac pacemakers.

نویسندگان

  • G D Green
  • W Forbes
  • W H Bain
  • G B Shaw
  • A C Kenmure
چکیده

Since 1958, totally implantable pacemakers have been used to stimulate the hearts of patients suffering from chronic heart block. The evidence that such patients have a reduced mortality rate in comparison with unpaced patients (Sowton, 1967) and the ability to return to a normal life have meant that pacemaker implantation for heart block is now accepted practice. There have been increasing numbers of reports on the improved reliability of such pacemakers (Parsonnet, Gilbert, and Zucker, 1966; Forbes et al., 1968; Sowton, 1968), but nevertheless failures do occur and it is most important that continued research into methods of anticipating and diagnosing such failures should continue. Sowton (1968) has emphasized the need for followup arrangements to be carried out at specially equipped clinics. At the same time, it should be appreciated that there is as yet no single test or method which will satisfactorily diagnose all possible faults (Dekker, Biller, and Schuilenburg, 1965). We have made a preliminary announcement of a method of testing the integrity of lead systems (Green et al., 1968) in which an analysis is made of the vector produced in the frontal plane by the pacemaker signal obtained using an oscilloscope and standard surface electrocardiographic electrodes. This paper reports the results of our experience in using this method in three Glasgow pacemaker clnics. As seen in an electrocardiogram, the pacemaker signal has the appearance of a sharp deflection immediately before the QRS complex, usually negative in leads I and II with a bipolar catheter and either positive or negative in lead III (Fig. 1). By excluding the electrocardiogram signal and examining the pacemaker signal on an oscilloscope (preferably a storage oscilloscope), the characteristics of the pacemaker signals can be seen in more detail (Fig. 1). The pacemaker signal is a "square-wave" pulse of electricity, two milliseconds or less in dura-

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experience with Implanted Pacemakers: Technical Considerations.

Between April 1960 and September 1964, 79 patients were treated with implanted pacemakers. We record here the technical difficulties encountered and the steps taken to overcome them. In all cases the indication for artificial pacing was failure of medical treatment to prevent Stokes-Adams attacks or to relieve cardiac failure due to a slow pulse. Most, but not all, patients were in complete hea...

متن کامل

Cardiac rhythm management devices (part I): indications, device selection, and function.

PACEMAKER1 and internal cardioverter–defibrillator (ICD) devices have undergone remarkable evolution since the first implantation of an asynchronous singlechamber pacemaker in 1958 and of an ICD in 1980. Today, more than 500,000 patients in the United States have pacemakers, and up to 115,000 new devices are implanted each year. The number of ICDs implanted each year has steadily increased, rea...

متن کامل

Anesthetic implications of implanted pacemakers: a case study.

Pacemakers and the underlying pathophysiologies leading to their implantation present challenges to the anesthetist. This case report discusses the anesthetic management of a patient with an implanted pacemaker. A case is presented of an 80-year-old female who was found unresponsive in a parking lot. She was diagnosed with a right parietal subdural hematoma. She underwent an emergency craniotom...

متن کامل

Use of real-time three-dimensional echocardiography to assess left ventricular systolic synchronization after dual-chamber pacing therapy

This study was designed to evaluate the left ventricular systolic synchronization in patients implanted with dual-chamber DDD mode cardiac pacemakers by real-time three-dimensional echocardiography (RT3DE). Twenty patients implanted with DDD mode cardiac pacemakers for 12 months and 20 healthy subjects underwent RT3DE. This method provided left ventricular end-diastolic volume (LEDV), left vent...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Trends in Cardiac Pacemaker Batteries

Batteries used in Implantable cardiac pacemakers-present unique challenges to their developers and manufacturers in terms of high levels of safety and reliability. In addition, the batteries must have longevity to avoid frequent replacements. Technological advances in leads/electrodes have reduced energy requirements by two orders of magnitude. Micro-electronics advances sharply reduce internal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 1969