In vitro optimisation of a microdialysis system with potential for on-line monitoring of lactate and glucose in biological samples.

نویسندگان

  • E Dempsey
  • D Diamond
  • M R Smyth
  • M A Malone
  • K Rabenstein
  • A McShane
  • M McKenna
  • T V Keaveny
  • R Freaney
چکیده

The optimisation and evaluation of the microdialysis component of a prototype miniaturised total analysis system for application in the continuous monitoring of lactate and glucose is reported. The complete unit comprises a high efficiency microdialysis sampling system, a miniaturised microflow manifold with an integrated biosensor array, together with the hardware and software necessary for controlling the flow parameters and monitoring the sensor signals. Sampling occurs via a microdialysis shunt probe which is perfused continuously with a physiological buffered saline solution. The continuous dialysate outflow is presented to the biosensor array, resulting in the appropriate amperometric signals. Aspects of technological significance addressed here include probe membrane size, perfusate flow rate, sample flow rate, temperature change, probe sterilisation procedures, and heparin content of the physiological saline solution employed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study

INTRODUCTION Tight glucose control in the ICU has been proven difficult with an increased risk for hypoglycaemic episodes. Also the variability of glucose may have an impact on morbidity. An accurate and feasible on-line/continuous measurement is therefore desired. In this study a central vein catheter with a microdialysis membrane in combination with an on-line analyzer for continuous monitori...

متن کامل

Evaluation of Cell Penetrating Peptide Delivery System on HPV16E7 Expression in Three Types of Cell Line

Background: The poor permeability of the plasma and nuclear membranes to DNA plasmids are two major barriers for the development of these therapeutic molecules. Therefore, success in gene therapy approaches depends on the development of efficient and safe non-viral delivery systems. Objectives: The aim of this study was to investigate the in vitro delivery of plasmid DNA encoding HPV16 E7 gene...

متن کامل

Simultaneous determination of glucose and L-lactate in rat brain by an electrochemical in vivo flow-injection system with an on-line microdialysis sampling.

An electrochemical in vivo flow-injection system with an on-line microdialysis sampling is proposed for the simultaneous monitoring of L-lactate and glucose in rat brain. In the first stage of the operation, the dialysate from the microdialysis probe is delivered to a sample loop of the six-way autoinjector by perfusing Ringer's solution for 80 s at 5 microl min(-1). In the second stage, the di...

متن کامل

Evaluation of Biochemical Parameters of Platelet Concentrates Stored in Plasma or in A Platelet Additive Solution (Composol)

Abstract Objective Removing plasma from the platelet concentrate (PC) medium could be an effective way to increase the safety of this product. The goal of this study was to compare PC stored in plasma or in an additive solution (Composol) with in vitro testing. Materials and Methods Fifty-four single donor PCs were prepared from Iranian Blood Transfusion Organization (IBTO). Each PC unit wa...

متن کامل

Continuous Monitoring of Subcutaneous Glucose and Lactate Using Microdialysis with On-Line Enzyme Electrodes

sayed by liquid chromatography, immunoassay, or capillary electrophoresis. The separation systems offer selective detection of analytes, but in many cases, the temporal resolution of the assay is not sufficient for continuous real-time monitoring of the microdialysate. These techniques are limited by the minimum sample volume required for practical sample handling and reliable measurements. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 122 2  شماره 

صفحات  -

تاریخ انتشار 1997