Determination of refractive indices of porcine skin tissues and intralipid at eight wavelengths between 325 and 1557 nm.
نویسندگان
چکیده
We constructed an automated reflectometry system for accurate measurement of coherent reflectance curves of turbid samples and analyzed the presence of coherent and diffuse reflection near the specular reflection angle. An existing method has been validated to determine the complex refractive indices of turbid samples on the basis of nonlinear regression of the coherent reflectance curves by Fresnel's equations. The complex refractive indices of fresh porcine skin epidermis and dermis tissues and Intralipid solutions were determined at eight wavelengths: 325, 442, 532, 633, 850, 1064, 1310, and 1557 nm.
منابع مشابه
Refractive indices of human skin tissues at eight wavelengths and estimated dispersion relations between 300 and 1600 nm.
The refractive index of human skin tissues is an important parameter in characterizing the optical response of the skin. We extended a previously developed method of coherent reflectance curve measurement to determine the in vitro values of the complex refractive indices of epidermal and dermal tissues from fresh human skin samples at eight wavelengths between 325 and 1557 nm. Based on these re...
متن کاملBulk optical parameters of porcine skin dermis at eight wavelengths from 325 to 1557 nm.
We introduce a method with which to obtain accurately the bulk optical parameters of fresh biological tissues in vitro by combining measurements of the sample surface profiles, reflectance, and transmittances with Monte Carlo-based inverse calculations. The bulk optical parameters of fresh porcine dermis tissue were determined at eight wavelengths from 325 to 1557 nm and were found to be much d...
متن کاملQuantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm
One of the present challenges in optical coherence tomography (OCT) is the visualization of deeper structural morphology in biological tissues. Owing to a reduced scattering, a larger imaging depth can be achieved by using longer wavelengths. In this work, we analyze the OCT imaging depth at wavelengths around 1300 nm and 1600 nm by comparing the scattering coefficient and OCT imaging depth for...
متن کاملFiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths.
We present a compact, fast, and versatile fiber-optic probe system for real-time determination of tissue optical properties from spatially resolved continuous-wave diffuse reflectance measurements. The system collects one set of reflectance data from six source-detector distances at four arbitrary wavelengths with a maximum overall sampling rate of 100 Hz. Multivariate calibration techniques ba...
متن کاملImprovement of the bulk sensitivity and FoM of the plasmonic nanodipole antenna array
In this paper, the sensitivity of a plasmonic nanodipole antenna array for different materials of the metal nanodipole and substrate is calculated by changing the refractive index of the surrounding medium. The performance of our proposed array is studied at two wavelengths of 1310 and 1550 nm, the wavelengths of the second and third telecommunications windows. It is shown that by using the sil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 22 6 شماره
صفحات -
تاریخ انتشار 2005