Time and resources of peripherally inserted central catheter insertion procedures: a comparison between blind insertion/chest X-ray and a real time tip navigation and confirmation system
نویسندگان
چکیده
BACKGROUND The Sherlock 3CG™ Tip Confirmation System (TCS) provides real-time peripherally inserted central catheter (PICC) tip insertion information using passive magnetic navigation and patient cardiac electrical activity. It is an alternative tip confirmation method to fluoroscopy or chest X-ray for PICC tip insertion confirmation in adults. The purpose of this study was to evaluate time and cost of the Sherlock 3CG TCS and blind insertion with chest X-ray tip confirmation (BI/CXR) for PICC insertions. METHODS A cross-sectional, observational Time and Motion study was conducted. Data were collected at four hospitals in the US. Two hospitals used Sherlock 3CG TCS and two hospitals used BI/CXR to place/confirm successful PICC tip location. Researchers observed PICC insertions, collecting data from the beginning (ie, PICC kit opening) to catheter tip confirmation (ie, released for intravenous [IV] therapy). An economic model was developed to project outcomes for a larger population. RESULTS A total of 120 subjects were enrolled, with 60 subjects enrolled in each arm and 30 enrolled at each of the four US hospitals. The mean time from initiation of the PICC procedure to the time to release for IV therapy was 33.93 minutes in the Sherlock 3CG arm and 176.32 minutes in the BI/CXR arm (p < 0.001). No malpositions were observed for PICC insertions using the Sherlock 3CG TCS, while 20% of subjects in the BI/CXR arm had a malposition. BI/CXR subjects had significantly more total malpositions (mean 0.23 vs. 0, p < 0.001). For a hypothetical population of 1,000 annual patients, adoption of Sherlock 3CG TCS was predicted to be cost saving compared with BI/CXR in all three analysis years. CONCLUSION The results from this study demonstrate that Sherlock 3CG TCS, when compared with BI/CXR, is a superior alternative with regard to time to release subject to therapy, malposition rates, and minimization of X-ray exposure.
منابع مشابه
Use of real-time ultrasound for locating tip position in neonates undergoing peripherally inserted central catheter insertion: A pilot study
BACKGROUND & OBJECTIVES Securing long-term venous access is an essential part of sick newborn care. The malposition of central line tip leads to several complications. There is a need for an easily available bedside investigating tool to diagnose these malpositions. This study was done to compare the effectiveness of real-time ultrasound (RTUS) with X-ray in identifying the peripherally inserte...
متن کاملModified insertion of a peripherally inserted central catheter: taking the chest radiograph earlier.
Placement of the tip of a peripherally inserted central catheter in the lower third of the superior vena cava is essential to minimize the risk of complications. Sometimes, however, the catheter tip cannot be localized clearly on the chest radiograph, and repositioning a catheter at bedside is difficult, sometimes impossible. A chest radiograph obtained just after the catheter is inserted, befo...
متن کاملWandering peripherally inserted central catheter tip: an under-recognised intensivist challenge.
To cite: Alwassia A, Chaubey VK, Patibandla B, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr2013-200313 DESCRIPTION A 75-year-old man with a history of atrial fibrillation presented with altered mental status. He was intubated in the emergency department for airway protection. A CT scan of the brain revealed multiple embolic strokes. He also developed asp...
متن کاملPericardial Effusion in an Extreme Low Birth Weight Neonate with Peripherally Inserted Central Catheter
Background: Pericardial effusion and cardiac tamponade are the rare complications of peripherally inserted central catheters (PICC insertion) in extreme low birth weight infants. In this regard, paying attention to these complications is of utmost importance, because they can result in infant death. Case report: The case of our infant is a sa...
متن کاملMachine Intelligence for Accurate X-ray Screening and Read-out Prioritization: PICC line Detection Study
A peripherally inserted central catheter (PICC) is a thin, flexible plastic tube that provides medium-term intravenous access for medicine, fluid, and chemotherapy administration. These are inserted into arm veins and threaded into the patient until the catheter tip reaches a large vein near the heart. As malpositioned PICCs can have potentially, serious complications, final position of all PIC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2017