Implementation of a sensitive, narrow-band Fourier-Transform Ion-Cyclotron-Resonance (FT-ICR) detection for short-lived radionuclides at SHIPTRAP*
نویسندگان
چکیده
A very promising way towards establishing an accurate description of the inner structure of an atomic nucleus is the study of exotic nuclei. In the last few years a number of mass spectrometers based on Penning traps have been setup at rare isotopes facilities [1]. For instance SHIPTRAP at GSI is designed to provide clean and cooled beams of singly charged radioactive ions produced in a fusion-evaporation reaction and separated in-flight by the velocity filter SHIP. The scientific goals include mass spectrometry, atomic and nuclear spectroscopy, and chemistry of transuranium species which are not available at ISOLor fragmentation facilities [2].
منابع مشابه
Detection Techniques for On-Line Mass Determination with Penning Traps
A Penning trap mass spectrometer is a well established instrument for the precise mass determination of both, stable and short-lived nuclides. For this purpose two different concepts are employed. Masses of stable species are mostly determined by the non-destructive detection of image currents induced in the trap electrodes and a subsequent Fourier transformation (FT). For short-lived nuclides ...
متن کاملFe- and Cu-Complex Formation with Artificial Ligands Investigated by Ultra-High Resolution Fourier-Transform ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS): Implications for Natural Metal-Organic Complex Studies
Citation: Waska H, Koschinsky A and Dittmar T (2016) Feand Cu-Complex Formation with Artificial Ligands Investigated by Ultra-High Resolution Fourier-Transform ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS): Implications for Natural Metal-Organic Complex Studies. Front. Mar. Sci. 3:119. doi: 10.3389/fmars.2016.00119 Feand Cu-Complex Formation with Artificial Ligands Investigated by Ultra...
متن کاملModification of trapping potential by inverted sidekick electrode voltage during detection to extend time-domain signal duration for significantly enhanced fourier transform ion cyclotron resonance mass resolution.
Applying an inverted voltage to the "sidekick" electrodes during ion cyclotron resonance detection improves both Fourier transform ion cyclotron resonance (FT-ICR) mass spectral signal-to-noise ratio (at fixed resolving power) and resolving power (at fixed signal-to-noise ratio). The time-domain signal duration increases by up to a factor of 2. The method has been applied to 7-T FT-ICR MS of el...
متن کاملFourier transform ion cyclotron resonance mass spectrometry: a primer.
This review offers an introduction to the principles and generic applications of FT-ICR mass spectrometry, directed to readers with no prior experience with the technique. We are able to explain the fundamental FT-ICR phenomena from a simplified theoretical treatment of ion behavior in idealized magnetic and electric fields. The effects of trapping voltage, trap size and shape, and other nonide...
متن کاملA glow discharge ion source with fourier transform ion cyclotron resonance mass spectrometric detection.
A glow discharge (CD) ion source has been coupled to a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer using a four-element electrostatic lens to accelerate and focus ions generated external to the instrument's high magnetic field into its analyzer cell. Like other CD mass spectrometers, GD-FT-ICR can provide a quantitative measure of bulk analyte concentration with good pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006