Mapping of noise impact provoked by the execution of foundation piles at high rise building sites.

نویسندگان

  • Adolpho Guido de Araújo
  • Alexandre Duarte Gusmão
  • Emilia Rahnemay Kohman Rabbani
  • Stela Paulino Fucale
چکیده

The objective of this work is to map, in a limited area inside and outside of the worksite, the environmental impact generated by sound pollution coming from the driving of foundation piles for high rise buildings, as well as to observe and check if the noise levels produced by the emitting source are tolerable in the urban environment. The methodology of the work includes a survey of technical references about the subject; measurement of noises surrounding the worksite during the foundation phase for four distinct buildings, with different types of piles: prefabricated piles, continuous helical displacement piles , traditional compaction piles and Terra Probe compaction piles. A grid of points was built due to the time of driving and after that the measurements of environmental noises were performed emitted by the execution of each type of pile using a sound level meter. The interpretation of the measurements and their impacts on the neighborhood of the building were performed using the computational tool Suffer for creating noise level contours. The X and Y axes of the grid represent the distances in meters of the area studied and the Z axis represents the noise measured in dB. The contours developed represent the mapping of the noise at the worksites and their surroundings. The mapping of the urban impact of noise, the measurement of its dimensions, and the examination of its propagation around the building are important subsides to adequate individual and collective protection procedures. Seventy one points were measured at four building sites with different types of piles, and the results showed that at only three points was the noise within the limits of the Municipal Law of Recife of 70 dB, which proves the relevance of the research. Finally, the comparative analysis between the four types of piles shows that the continuous helical displacement pile emits the lowest noise level among the four pile types studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Experimental Study of Foundation Underpinning by Piles

Existing buildings sometimes experience excessive settlement under their design loads or face the prospect of excessive settlement in the future if a change of building use is required and increased foundation loadings will occur. Several methods of foundation enhancement are available to arrest settlements or improve the future performance of existing foundations including the method of underp...

متن کامل

Analysis of non-connected piled raft foundations (NCPRF) with cushion by finite element method

For the optimum design of Piled Raft Foundations (PRF), the concept of settlement reducer piles has been applied. However, when these piles are connected to the raft, a high stress may develop in the relatively small number of piles. Therefore, an alternative approach is to disconnect the piles from the raft forming a new system called a non-connected or disconnected piled-raft foundation (NCPR...

متن کامل

Investigating the role of high-rise building shell elements in reducing energy consumption (case example: Isfahan Cascade doctors' residential towers)

Significant energy is used to provide and maintain environmental conditions for thermal comfort in high-rise residential buildings, which largely depends on the components of the shell design. Therefore, to achieve high amounts of energy savings in buildings, high-impact design measures must first be defined and then optimized. This study seeks to answer the question of how the components of th...

متن کامل

Simulation of Smoke Emission from Fires in High-Rise Buildings Using the 3D Model Generated from 2-Dimensional Cadastral Data

Having a 3-Dimensional model of high-rise buildings can be used in disaster management such as fire cases to reduce casualties. The fundamental dilemma in 3D building modeling is the unavailability of suitable data sources. However, available cadastral 2D maps could be used as low-cost and attainable resources for 3D building modeling. Smoke will be a great threat to people's health during a f...

متن کامل

Experimental Study of a Square Foundation with Connected and Non-Connected Piled Raft Foundation Under Eccentrically Loaded

In the recent years, non-connected piled raft foundation has been considered as an economical and practical deep foundation in the situation that high shear and concentrated loads may occur at the connection of the raft and pile head. This paper was presented an experimental study of a square foundation on the effects of parameters such as S/D, L/D and etc. in two cases of connected or non-conn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Work

دوره 41 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2012