Effect of Guglielmi detachable coil placement on intraaneurysmal pressure: experimental study in canines.

نویسندگان

  • A Sorteberg
  • W Sorteberg
  • A S Turk
  • A Rappe
  • P H Nakstad
  • C M Strother
چکیده

BACKGROUND AND PURPOSE Treatment of ruptured aneurysms with Guglielmi detachable coils (GDCs) has been shown to prevent repeat bleeding. To assess whether GDC coiling alters aneurysmal pressure, we measured intraaneurysmal pressure in two canine types of carotid artery aneurysms before and after GDC placement. METHODS A 0.014-inch guidewire with a pressure transducer was inserted into parent arteries and domes of surgically created aneurysms. Intravascular static pressures were recorded before and during saline power injections (10, 20, and 30 mL over 1 and 2 s), before and after GDC placement. Common femoral arterial pressure was monitored. RESULTS Saline power injections reproducibly and abruptly increased pressure in parent arteries and aneurysms. Mean intraaneurysmal pressure varied (18 +/- 4 [10 mL] to 75 +/- 15 mm Hg [30 mL]), independent of injection duration. Intraaneurysmal baseline pressures were higher after GDC placement (111 +/- 10 versus 93 +/- 15 mm Hg; P =.05). Aneurysmal pressure increases with saline injections were slightly higher after GDC placement, which dampened intraaneurysmal pressure amplitude at baseline (26.5 +/- 5.6 versus 19.6 +/- 7.4 mm Hg; P =.003) and during hypertension (25.3 +/- 5.4 versus 19.8 +/- 7.5 mm Hg, P =.002). The pressure increase slope with saline injection was delayed with GDC placement (0.24 +/- 0.1 versus 0.38 +/- 0.19 s; P <.001). CONCLUSION Graded saline power injections into parent arteries can rapidly increase intraaneurysmal pressure. GDC treatment did not attenuate mean intraaneurysmal pressures, but both dampened the pressure amplitude and delayed pressure increases during locally induced hypertension.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Guglielmi detachable coils on intraaneurysmal flow: experimental study in canines.

BACKGROUND AND PURPOSE Guglielmi detachable coils (GDCs) are effective in preventing rebleeding of ruptured aneurysms. To better understand the mechanism underlying this protective effect, we evaluated blood flow in aneurysms and their parent arteries before and after GDC coil placement. METHODS An 0.14-inch guidewire containing a combined pressure and thermistor sensor was inserted through a...

متن کامل

Thrombosis in giant basilar tip aneurysms during coil embolization.

Two patients with giant basilar tip aneurysms underwent coil embolization, one with both platinum fiber and platinum Guglielmi detachable coils and the other with Guglielmi detachable coils only. In both cases, spontaneous intraaneurysmal thrombosis occurred outside the coil mass, presumably a result of disruption of the intraaneurysmal flow pattern.

متن کامل

MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils.

The Guglielmi detachable coil, a platinum microcoil used in the endovascular treatment of intracranial aneurysms, was studied in vitro for its MR imaging artifacts, heat production, and ferromagnetism. In addition, imaging artifacts were studied in vivo in eight patients who had undergone therapeutic placement of these coils. These devices displayed a very low level of MR artifact and no ferrom...

متن کامل

Topic review: surface modifications enhancing biological activity of guglielmi detachable coils in treating intracranial aneurysms.

BACKGROUND Endovascular therapy with Guglielmi detachable coils is an accepted treatment option for patients with intracranial aneurysms. However, an emerging technology in the realm of endovascular tools is the use of traditional Guglielmi detachable coils with biologically active substances complexed to the coil surface to enhance aneurysm occlusion. METHODS We review the literature and cur...

متن کامل

Unruptured intracranial aneurysms: a call for a randomized clinical trial.

1. Kallmes DF, Fujiwara NH, Yuen D, et al. A collagen-based coil for embolization of saccular aneurysms in a New Zealand White rabbit model. AJNR Am J Neuroradiol 2003;24:591–96 2. Dawson RC 3rd, Shengelaia GG, Krisht AF, et al. Histologic effects of collagenfilled interlocking detachable coils in the ablation of experimental aneurysms in swine. AJNR Am J Neuroradiol 1996;17:853–58 3. Murayama ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 2001