The Henry Ford production system: LEAN process redesign improves service in the molecular diagnostic laboratory: a paper from the 2008 William Beaumont hospital symposium on molecular pathology.
نویسندگان
چکیده
Accurate and timely molecular test results play an important role in patient management; consequently, there is a customer expectation of short testing turnaround times. Baseline data analysis revealed that the greatest challenge to timely result generation occurred in the preanalytic phase of specimen collection and transport. Here, we describe our efforts to improve molecular testing turnaround times by focusing primarily on redesign of preanalytic processes using the principles of LEAN production. Our goal was to complete greater than 90% of the molecular tests in less than 3 days. The project required cooperation from different laboratory disciplines as well as individuals outside of the laboratory. The redesigned processes involved defining and standardizing the protocols and approaching blood and tissue specimens as analytes for molecular testing. The LEAN process resulted in fewer steps, approaching the ideal of a one-piece flow for specimens through collection/retrieval, transport, and different aspects of the testing process. The outcome of introducing the LEAN process has been a 44% reduction in molecular test turnaround time for tissue specimens, from an average of 2.7 to 1.5 days. In addition, extending LEAN work principles to the clinician suppliers has resulted in a markedly increased number of properly collected and shipped blood specimens (from 50 to 87%). These continuous quality improvements were accomplished by empowered workers in a blame-free environment and are now being sustained with minimal management involvement.
منابع مشابه
Lean six sigma process improvement in specimen receiving to improve stat chemistry turnaround times
Objective: As a consequence of stat turnaround times (TATs) chronically exceeding 60 minutes, our laboratory was facing pressure to divert limited resources toward the implementation of an emergency department satellite laboratory. Peer-reviewed literature in clinical laboratory quality assurance and improvement indicates that between 60-70% of errors occur at the pre-analytical level. Thus...
متن کاملThe Henry Ford Production System: reduction of surgical pathology in-process misidentification defects by bar code-specified work process standardization.
Misidentification defects are a potential patient safety issue in medicine, including in the surgical pathology laboratory. In addressing the Joint Commission's national patient safety goal of accurate patient and specimen identification, we focused our lens internally on our own laboratory processes, with measurement tools designed to identify potential misidentification defects and their root...
متن کاملDaily Management System of the Henry Ford Production System: QTIPS to Focus Continuous Improvements at the Level of the Work.
OBJECTIVES To support our Lean culture of continuous improvement, we implemented a daily management system designed so critical metrics of operational success were the focus of local teams to drive improvements. METHODS We innovated a standardized visual daily management board composed of metric categories of Quality, Time, Inventory, Productivity, and Safety (QTIPS); frequency trending; root...
متن کاملTransforming to a Quality Culture The Henry Ford Production System
We describe the cultural transformation of the surgical pathology laboratory at Henry Ford Hospital, Detroit, MI, to one that has adopted an expectation for empowered workers to see their daily work in the context of continually learning and making effective process improvements that are designed and tested by the scientific method. This transformation has been achieved by creating an organizat...
متن کاملComplete ablation of tumor necrosis factor decreases the production of IgA, IgG, and IgM in experimental central nervous system tuberculosis
Objective(s): This study aimed to explore the contribution of tumor necrosis factor (TNF) in the recruitment of B-cell and secretion of immunoglobulins (Igs) during cerebral tuberculosis (TB).Materials and Methods: In this work, the contributing role of TNF in regulating Ig secretions was investigated by comparing wild type TNF (TNFf/f),...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of molecular diagnostics : JMD
دوره 11 5 شماره
صفحات -
تاریخ انتشار 2009