A comprehensive model for power line interference in biopotential measurements

نویسندگان

  • Mireya Fernandez-Chimeno
  • Ramon Pallàs-Areny
چکیده

Power line interference is a major problem in high-resolution biopotential measurements. Because interference coupling is mostly capacitive, shielding electrode leads and a high common-mode rejection ratio (CMRR) are quite effective in reducing power-line interference but do not completely eliminate it. We propose a model that includes both interference external to the measuring system and interference coming from its internal power supply. Moreover, the model considers interference directly coupled to the measuring electrodes, because, as opposed to connecting leads, electrodes are not usually shielded. Experimental results confirm that reducing interference coupled through electrodes yields a negligible interference. The proposed model can be applied to other differential measurement systems, particulary those involving electrodes or sensors placed far apart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power

Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...

متن کامل

Microcontroller-based Biopotential Data Acquisition Systems: Practical Design Considerations

Non-invasive bioimpedance measurements are an important part of routine diagnostic procedures. ECG (Electrocardiograph), EEG (Electroencephalograph), EMG (Electromyography) and EOG (Electrooculograph) measurements are amongst the most common non-invasive measurements used for diagnosis. The advances in microcontroller technology over the past 25 years have resulted in general-purpose, low-cost,...

متن کامل

Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular s...

متن کامل

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the bod...

متن کامل

Power Line Interference Cancelling in EEG Inspection

This paper presents a FIR adaptive filter to cancelling interference due to 50 Hz power line in human electroencephalographic (EEG) inspection. An overview of EEG techniques to study brain activity will be outlined. Then, the problem of spurious signal rejection, in this particular handset, shows the meaningfull application of adaptive filter structure. Poles of filter are driven to find an opt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • IEEE Trans. Instrumentation and Measurement

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2000