Percutaneous extraction of endocardial leads--a single centre experience in 120 patients.

نویسندگان

  • Andrzej Kutarski
  • Barbara Małecka
  • Piotr Ruciński
  • Andrzej Zabek
چکیده

BACKGROUND The expanding number of patients treated with pacing, especially resynchronisation therapy and pacing system upgrades as well as leads remaining inactive, and prolonged life expectancy are the causes of an increase of the number of electrodes in pacemaker patients. The growing problem with endocardial lead infections and excess leads has made percutaneous lead removal technology widespread as it is less invasive than cardiosurgery. AIM We present our experience in percutaneous lead removal in a single reference centre in Poland. METHODS During 2.5 years, 236 leads in 120 patients were removed. The criterion for inclusion in the present analysis was the age of the oldest lead: > 12 months in pacemaker patients and > 6 months in patients with implantable cardioverter-defibrillators (ICD). All patients admitted to the hospital for lead removal underwent a percutaneous procedure. The age of the patients ranged from 18 to 87 (mean 65.7) years. The leads were removed using the Lead Extraction System (Cook) with the rotational cutting force only, notlaser or RF energy. RESULTS Indications for lead removal were: local (pocket) infection (47%), endocarditis (27%) and lead excess (26%). Seventy six percent of patients had at least two pacemaker/ICD-related procedures whereas 24% had only one implantation procedure in the past. The median time from the preceding procedure was 12 months. In 38 patients there were 60 inactive electrodes. The majority of patients had two (62%) or three (19%) leads, followed by 12% with one lead and 7% of patients with more than three leads. In 27.5% of patients leads from the coronary sinus were removed. The complication rate was 4%. CONCLUSIONS Percutaneous lead removal procedures are performed in Poland for class I and II indications according to NASPE classification. In many cases patients had multiple leads, including in the coronary sinus. The majority of patients had two or more interventions in the past.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy of the Percutaneous Nephrolithotomy in Pediatrics; A 10-year single-center experience in Iran

Background: The aim of this study was to describe the one-decade experience in Percutaneous Nephrolithotomy surgery in children with kidney stones in Tehran, Iran. Methods: All patients (less than 18 years old) undergoing Percutaneous Nephrolithotomy at our referral medical center, were reviewed in this cross-sectional study. All the demographics, surgical data and post-operative information...

متن کامل

A 10 year single centre experience of percutaneous and endoscopic extraction of bile duct stones with T tube in situ.

A non-randomised single centre study of 226 consecutive patients referred over 10 years with retained common bile duct stones and a T tube in situ or a cholecystostomy tube are reported. Percutaneous extraction was attempted in 204 and endoscopic extraction in 68 patients. Percutaneous clearance was achieved in 158 (77.5%) patients and endoscopic clearance in 52 (76.5%) patients. Six of 153 (3....

متن کامل

Lead extraction in children and young adults using different techniques.

OBJECTIVE To describe our experience with removal of pacing lead in children using different techniques. PATIENTS AND METHODS Between 1999 and 2006, removal of 39 leads was attempted in 30 patients: 21 males and 9 females aged 4-21 years (mean 12 +/- 5 years). Sixteen patients had previous corrective cardiac surgery. The leads had been implanted for 46 +/- 31 months (range 1-120 months). The ...

متن کامل

Transvenous extraction of cardiac rhythm device leads: a report of the experience from a single referral centre in Greece.

INTRODUCTION As rates of implanted cardiac electronic devices continue to rise, lead extraction procedures are crucial for the management of complications. The optimal method for such procedures has been constantly debated. We sought to review our experience of lead extraction using a conventional technique. METHODS This was a retrospective study of lead extraction procedures in a major refer...

متن کامل

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 67 2  شماره 

صفحات  -

تاریخ انتشار 2009