Transmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy.

نویسندگان

  • Ayano Tanabe
  • Terumasa Hibi
  • Sari Ipponjima
  • Kenji Matsumoto
  • Masafumi Yokoyama
  • Makoto Kurihara
  • Nobuyuki Hashimoto
  • Tomomi Nemoto
چکیده

All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with an optical clearing reagent. In this study, we developed a transmissive device that corrects primary coma aberration and astigmatism. The motivation for this study is that asymmetric aberration can be induced by the shape of a biospecimen and/or by a complicated refractive-index distribution in a sample; this can considerably degrade optical performance even near the sample surface. The device’s performance was evaluated by observing fluorescence beads. The device was inserted between the objective lens and microscope revolver and succeeded in improving the spatial resolution and fluorescence signal of a bead image that was originally degraded by asymmetric aberration. Finally, we implemented the device for observing a fixed whole mouse brain with a sloping surface shape and complicated internal refractive-index distribution. The correction with the device improved the spatial resolution and increased the fluorescence signal by ?2.4×. The device can provide a simple approach to acquiring higher-quality images of biospecimens.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting spherical aberrations in a biospecimen using a transmissive liquid crystal device in two-photon excitation laser scanning microscopy.

Two-photon excitation laser scanning microscopy has enabled the visualization of deep regions in a biospecimen. However, refractive-index mismatches in the optical path cause spherical aberrations that degrade spatial resolution and the fluorescence signal, especially during observation at deeper regions. Recently, we developed transmissive liquid-crystal devices for correcting spherical aberra...

متن کامل

Rapid measurement of low-order aberrations using Fourier transforms of crystalline Ronchigrams.

The aberrations of the objective lens should be measured and adjusted to realize high spatial resolution in scanning transmission electron microscopy (STEM). Here we report a method of measuring low-order aberrations using the Fourier transforms of Ronchigrams of an arbitrary crystal such as a specimen of interest. We have applied this technique to measure first- and second-order geometrical ab...

متن کامل

Two-photon microscopy with wavelength switchable fiber laser excitation.

Two-photon scanning fluorescence microscopy has become a powerful tool for imaging living cells and tissues. Most applications of two-photon microscopy employ a Ti:sapphire laser excitation source, which is not readily portable or rapidly tunable. This work explores the use of two-photon fiber laser excitation (TP-FLEX) as an excitation source for scanning two-photon microscopy. We have further...

متن کامل

Retrospective analysis of changes in the anterior corneal surface after Q value guided LASIK and LASEK in high myopic astigmatism for 3 years

BACKGROUND To compare the corneal high-order aberrations (HOAs), asphericity and regularity after Q-value guided laser in situ keratomileusis (LASIK) and laser epithelial keratomileusis (LASEK) in high myopic astigmatism. METHODS In this retrospectively comparative study, we measured the corneal HOAs, asphericity indices (Q values) and corneal regularity indices preoperatively and 36 months p...

متن کامل

The Effects of Excitation Signal on the Resolution of the Liquid Crystal Capacitive Chemical and Biological Sensors

In this paper excitation characteristics of the Liquid Crystal (LC) capacitive chemical and biological sensor are examined and the optimum frequency and voltage range for the sensor interface are introduced. Interdigitated capacitor has been used for the sensor capacitance measurement and two different molecular orientations, homeotropic and homogenous, have been considered. The LC sensor capac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 21 12  شماره 

صفحات  -

تاریخ انتشار 2016