MR-based assessment of body fat distribution and characteristics.
نویسندگان
چکیده
The assessment of body fat distribution and characteristics using magnetic resonance (MR) methods has recently gained significant attention as it further extends our pathophysiological understanding of diseases including obesity, metabolic syndrome, or type 2 diabetes mellitus, and allows more detailed insights into treatment response and effects of lifestyle interventions. Therefore, the purpose of this study was to review the current literature on MR-based assessment of body fat distribution and characteristics. PubMed search was performed to identify relevant studies on the assessment of body fat distribution and characteristics using MR methods. T1-, T2-weighted MR Imaging (MRI), Magnetic Resonance Spectroscopy (MRS), and chemical shift-encoding based water-fat MRI have been successfully used for the assessment of body fat distribution and characteristics. The relationship of insulin resistance and serum lipids with abdominal adipose tissue (i.e. subcutaneous and visceral adipose tissue), liver, muscle, and bone marrow fat content have been extensively investigated and may help to understand the underlying pathophysiological mechanisms and the multifaceted obese phenotype. MR methods have also been used to monitor changes of body fat distribution and characteristics after interventions (e.g. diet or physical activity) and revealed distinct, adipose tissue-specific properties. Lastly, chemical shift-encoding based water-fat MRI can detect brown adipose tissue which is currently the focus of intense research as a potential treatment target for obesity. In conclusion, MR methods reliably allow the assessment of body fat distribution and characteristics. Irrespective of the promising findings based on these MR methods the clinical usefulness remains to be established.
منابع مشابه
ارتباط نمایه توده بدنی و الگوی توزیع چربی بدن با سرم لیپیدی خون در دختران فعال و غیرفعال مقطع راهنمایی
Background and purpose: This study aimed at determining the relationship between the body mass index and pattern of fat distribution with blood lipid serum among secondary school girls. Materials and methods: A total of 780 students who volunteered to participate in this study signed an informed consent form. Among them 155 were active, 340 were inactive and 285 students were moderately active...
متن کاملA Method for Body Fat Composition Analysis in Abdominal Magnetic Resonance Images Via Self-Organizing Map Neural Network
Introduction: The present study aimed to suggest an unsupervised method for the segmentation of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) in axial magnetic resonance (MR) images of the abdomen. Materials and Methods: A self-organizing map (SOM) neural network was designed to segment the adipose tissue from other tissues in the MR images. The segmentation of SAT and VA...
متن کاملThe Effects of L-Carnitine and Different Levels of Animal Fat on Performance, Carcass Characteristics, some Blood Parameters and Immune Response in Broiler Chicks
This study was conducted to investigate the effects of L-carnitine and different levels of animal fat on performance, carcass characteristics and some blood parameters of broiler chickens. Two hundred one-day old male broiler chicks were allotted to5 treatments in 4 replicates and 10 birds in each replicate. Dietary treatments consisted of: 1) diet with 5% vegetable oil (T1), 2) diet with 5% ve...
متن کاملComparison of Fat Distribution Parameters between Individuals with and without Metabolic Syndrome
Abstract Objective: The aim of this study was to compare the body fat parameters in individuals with and without metabolic syndrome using an objective method. Materials and methods: This case-control study was performed in Tehran and consisted of 105 individuals with age range of 20 to 55 years. All participants were overweight and obese. NCEP ATP III criteria were used for identifying subjec...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of radiology
دوره 85 8 شماره
صفحات -
تاریخ انتشار 2016