BACKGROUND Interpretive performance of screening mammography varies substantially by facility, but performance of diagnostic interpretation has not been studied. METHODS Facilities performing diagnostic mammography within three registries of the Breast Cancer Surveillance Consortium were surveyed about their structure, organization, and interpretive processes. Performance measurements (false-positive rate, sensitivity, and likelihood of cancer among women referred for biopsy [positive predictive value of biopsy recommendation {PPV2}]) from January 1, 1998, through December 31, 2005, were prospectively measured. Logistic regression and receiver operating characteristic (ROC) curve analyses, adjusted for patient and radiologist characteristics, were used to assess the association between facility characteristics and interpretive performance. All statistical tests were two-sided. RESULTS Forty-five of the 53 facilities completed a facility survey (85% response rate), and 32 of the 45 facilities performed diagnostic mammography. The analyses included 28 100 diagnostic mammograms performed as an evaluation of a breast problem, and data were available for 118 radiologists who interpreted diagnostic mammograms at the facilities. Performance measurements demonstrated statistically significant interpretive variability among facilities (sensitivity, P = .006; false-positive rate, P < .001; and PPV2, P < .001) in unadjusted analyses. However, after adjustment for patient and radiologist characteristics, only false-positive rate variation remained statistically significant and facility traits associated with performance measures changed (false-positive rate = 6.5%, 95% confidence interval [CI] = 5.5% to 7.4%; sensitivity = 73.5%, 95% CI = 67.1% to 79.9%; and PPV2 = 33.8%, 95% CI = 29.1% to 38.5%). Facilities reporting that concern about malpractice had moderately or greatly increased diagnostic examination recommendations at the facility had a higher false-positive rate (odds ratio [OR] = 1.48, 95% CI = 1.09 to 2.01) and a non-statistically significantly higher sensitivity (OR = 1.74, 95% CI = 0.94 to 3.23). Facilities offering specialized interventional services had a non-statistically significantly higher false-positive rate (OR = 1.97, 95% CI = 0.94 to 4.1). No characteristics were associated with overall accuracy by ROC curve analyses. CONCLUSIONS Variation in diagnostic mammography interpretation exists across facilities. Failure to adjust for patient characteristics when comparing facility performance could lead to erroneous conclusions. Malpractice concerns are associated with interpretive performance.
منابع مشابه
Mammography Facility Characteristics Associated With Interpretive Accuracy of Screening Mammography
BACKGROUND Although interpretive performance varies substantially among radiologists, such variation has not been examined among mammography facilities. Understanding sources of facility variation could become a foundation for improving interpretive performance. METHODS In this cross-sectional study conducted between 1996 and 2002, we surveyed 53 facilities to evaluate associations between fa...
متن کاملRadiologist characteristics associated with interpretive performance of diagnostic mammography.
BACKGROUND Extensive variability has been noted in the interpretive performance of screening mammography; however, less is known about variability in diagnostic mammography performance. METHODS We examined the performance of 123 radiologists who interpreted 35895 diagnostic mammography examinations that were obtained to evaluate a breast problem from January 1, 1996, through December 31, 2003...
متن کاملDiagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملVariability in interpretive performance at screening mammography and radiologists' characteristics associated with accuracy.
PURPOSE To identify radiologists' characteristics associated with interpretive performance in screening mammography. MATERIALS AND METHODS The study was approved by institutional review boards of University of Washington (Seattle, Wash) and institutions at seven Breast Cancer Surveillance Consortium sites, informed consent was obtained, and procedures were HIPAA compliant. Radiologists who in...
متن کاملAccess to diagnostic mammography in the San Francisco Bay Area.
BACKGROUND It is important to assess access to diagnostic mammography because of the high likelihood of breast cancer among women who need diagnostic evaluation. We studied access to diagnostic mammography in the Greater San Francisco Bay Area. METHODS We identified facilities that provide diagnostic mammography in nine counties in Northern California. We tried to schedule a diagnostic mammog...