Letter to the Editor: Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study.

نویسندگان

  • Harun Mutlu
  • Serhat Mutlu
چکیده

PURPOSE To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. METHODS 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55º and 63º (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated screws (n=6), 6.5-mm cannulated screws (n=6), or 7.3-mm cannulated screws (n=6). A custom-built jig was designed to guide the insertion of the screws in an identical triangular configuration. Screws were tightened by a single operator using a torque-measuring screwdriver. The femoral head was subjected to progressive axial loading at 5 mm/min. The load to failure and displacement were recorded. RESULTS The 3 groups did not differ significantly except that the load to failure was higher in the construct with 6.5-mm non-cannulated screws than that with 6.5-mm cannulated screws (1222 N vs 1008 N, p=0.003). CONCLUSION The compressive strength of a synthetic bone hip fracture model fixed with non-cannulated screws was higher than that of cannulated screws of the same diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study

Purpose. To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. Methods. 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55o and 63o (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...

متن کامل

Subtrochanteric fracture: a rare but severe complication after screw fixation of femoral neck fractures in the elderly.

Cannulated screw fixation is a minimal invasive technique to treat undisplaced femoral neck fractures. It is the preferred method in elderly patients who often suffer co-morbidities. There is scarce literature on subtrochanteric femoral fracture as a complication of cannulated screw fixation of a femoral neck fracture. This complication occurred, without an adequate trauma, in two of 35 patient...

متن کامل

Cannulated Screw Fixation For Femoral Neck Fractures : A 5-year Experience In A Single Institution

ABSTRACT Cannulated screw fixation is a widely accepted surgical method for management of fractures of the neck of femur especially in patients with poor premorbid conditions, minimally displaced fractures and those from a younger age group. A five year retrospective study was carried out in 53 consecutive patients between 2006 to 2010 to determine the pattern of injuries, management, outcomes ...

متن کامل

Biomechanical comparison of dynamic hip screw, proximal femoral nail, cannulated screw, and monoaxial external fixation in the treatment of basicervical femoral neck fractures.

PURPOSE OF THE STUDY The objective of this study was to establish relative fixation strengths of proximal femoral nail (PFN), dynamic hip screw (DHS), monolateral external fixator (EF), and cannulated screw (CS) in basicervical hip fracture model. MATERIAL AND METHODS The study involved four groups of implanted composite proximal femoral synthetic bones of eight specimens per group; nailing wit...

متن کامل

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2015