Investigation of nitrite adulteration on the immunoassay and GC-MS analysis of cannabinoids in urine specimens.

نویسندگان

  • L S Tsai
  • M A ElSohly
  • S F Tsai
  • T P Murphy
  • B Twarowska
  • S J Salamone
چکیده

Nitrite ion has been identified as the active ingredient of two commercial adulterants that could cause discrepant results between the immunoassay screening and gas chromatographic-mass spectrometric (GC-MS) confirmation of 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in urine. Procedures to chemically convert the nitrite ion at the beginning of sample preparation for GC-MS analysis may not overcome all nitrite adulteration cases because portions of the THCCOOH might have been lost between the time of sample collection and the time of analysis. This study was conducted to further investigate the influence of both urine sample matrix and the duration of nitrite exposure on nitrite interference of THCCOOH detection. Forty clinical "THC-positive samples" that had been screened and confirmed positive for the presence of THCCOOH were spiked with 0.15M or 0.3M of nitrite. The levels of THCCOOH at various time intervals after nitrite spiking were monitored by instrument-based cannabinoids immunoassays (Syva EMIT d.a.u. and/or Roche Abuscreen ONLINE assays) and by an onsite THC immunoassay (Roche ONTRAK TESTSTIK). Results from this report demonstrate that the two outstanding "urine specimen factors" that dictated the effectiveness of the nitrite adulteration were urinary pH and the original drug concentration before nitrite spiking. Significant decreases in the immunoassay results could be observed within 4 h of nitrite treatment in the majority of samples with acidic urinary pH values. Regardless of their original concentration of THCCOOH (GC-MS ranging from 33 to 488 ng/mL), all of the 20 samples that had acidic pH values gave negative immunoassay results 1 day after nitrite adulteration. In contrast, the immunoassay results of samples with neutral or basic pH values were less affected by nitrite exposure in the same studies. Approximately two-thirds of the samples with pH values greater than 7.0 remained immunoassay-positive 3 days after nitrite spiking. Nevertheless, some of the adulterated urine that showed no change in immunoassay results might exhibit significant decrease in GC-MS recoveries even with bisulfite treatment, collaborating with the observations that a portion of samples screened positive with THC immunoassay in the laboratory could fail to confirm with GC-MS analysis. The decrease or loss of immunoassay detectable cannabinoid cross-reactives in acidic "THC-positive samples" can be attenuated by chemically increasing the pH value of the samples to the basic pH range.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retraining over the principles and mechanisms involved in the occurrence of false results from urine drug screening tests: Adulteration and strategies to defeat

Screening tests (UDSTs) for the diagnosis of psychoactive drugs can identify drug abuse, improve workplace safety, ensure community health, and play a critical role in therapeutic drug monitoring. Nonetheless, correct interpretation of the results of these tests requires a full awareness of the principles of testing methods, drug kinetics, and various leading causes of false results. Among the ...

متن کامل

Detection of marijuana use by oral fluid and urine analysis following single-dose administration of smoked and oral marijuana.

We compared oral fluid testing to urine testing in subjects who were administered single doses of marijuana by smoked and oral routes. Oral fluid specimens were collected with the Intercept DOA Oral Specimen Collection Device, screened for THC with the Cannabinoids Intercept MICRO-PLATE Enzyme Immunoassay (EIA) utilizing a 1.0-ng/mL cutoff concentration, and confirmed for THC by gas chromatogra...

متن کامل

Integrity of Urine Specimens for Toxicological Analysis - Adulteration, Mechanisms of Action, and Laboratory Detection.

Drug testing in urine for employees is an important deterrent for drug abuse. Because of the dire consequences of a positive result, many individuals who might otherwise test positive will go to great lengths to escape detection. The term "adulteration" in this context refers to: substitution of drug-free urine, purposeful ingestion of agents or fluids designed to either accelerate drug clearan...

متن کامل

Laboratory analysis of remotely collected oral fluid specimens for opiates by immunoassay.

The performance characteristics of a method for detecting opiates (morphine, codeine, heroin, and 6-acetylmorphine [6-AM]) in oral fluid specimens were examined and compared with methods for urine specimens. The oral fluid was easily obtained using a simple device that collects between 1 and 1.5 mL of fluid for laboratory analysis. Simultaneously collected specimens from 60 known opiate abusers...

متن کامل

Papain: a novel urine adulterant.

The estimated number of employees in the United Stated screened annually for illicit drugs is approximately 20 million, with marijuana being the most frequently abused drug. Urine adulterants provide an opportunity for illicit drug users to obtain a false-negative result on commonly used primary drug screening methods such as the enzyme multiplied immunoassay technique and the fluorescence pola...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 24 8  شماره 

صفحات  -

تاریخ انتشار 2000