Patient dose from barium procedures.

نویسندگان

  • R Ruiz-Cruces
  • F Ruiz
  • M Pérez-Martínez
  • J López
  • I Tort Ausina
  • A D de los Ríos
چکیده

The objective of this work was to estimate patient doses (dose-area product, organ dose, effective dose and entrance surface dose) for barium procedures. A total of 175 procedures, in 175 patients, for five different examination categories was analysed. Dose-area product was determined using a transmission ionization chamber. Organ dose and effective dose were assessed using a knowledge of the examination and the software. For all patients, the contribution of fluoroscopy to the total dose was greater than that from radiography. Dose-area product from double contrast barium enema, enteroclysis and intestinal tract procedures was higher than that obtained for the other procedures. The average effective dose was 1.04 mSv and 13.99 mSv for oesophageal tract and enteroclysis examinations, respectively. Entrance surface dose in the oesophageal tract was 16 mGy, 10 times lower than for the other four procedures. Patient dose reduction in barium procedures may be achieved by improved training of resident radiologists, senior radiologists and other specialists in radiation protection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation dose measurement in gastrointestinal studies.

Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedure...

متن کامل

تخمین میزان پرتوگیری بیماران از تصویربرداری رادیوگرافی در بیمارستان های ارجاعی دولتی شهر ساری

Background and purpose: Estimation of the risks of radiation would be possible by identifying the dose received. Introducing the dose level from diagnostic procedures can be effective in reducing the patient dose, improving the quality of treatment, and increasing the safety of patients and staff. This study evaluated patient entrance surface dose (ESD), effective dose, and cumulative dose from...

متن کامل

Staff and patient absorbed doses due to diagnostic nuclear medicine procedures

Background: Annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. Annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a phy...

متن کامل

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

Fetus Dose Estimation in Computed Tomography Procedures

Computed Tomography (CT) procedures constitute the 5% of the total diagnostic radiology and provide more than the 40% of the total dose. Patient dose depends on many factors; most of them depend on the way the procedure is performed. All around the world, there is a growing interest in studying patient dose in CT procedures in order to optimize them. If the patient is pregnant, conceptus absorb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 73 871  شماره 

صفحات  -

تاریخ انتشار 2000