Real-time PCR diagnostics failure caused by nucleotide variability within exon 4 of the human cytomegalovirus major immediate-early gene.
نویسندگان
چکیده
Here we report how variability in the human cytomegalovirus genome sequence may seriously affect the outcome of its molecular diagnosis. A real-time quantitative PCR assay targeting the major immediate-early gene failed to detect the viral load in some, but not all, clinical samples from hematooncological patients. By amplification and sequencing the DNA across the regions targeted by this assay we found a number of nucleotide substitutions which accounted for decreased primer/probe binding. This decreased the sensitivity of the assay up to 1,000-fold.
منابع مشابه
Exon 4 of the Human Cytomegalovirus (CMV) Major Immediate-Early Gene as a Target for CMV Real-Time PCR
Lengerova et al. recently published on the failure of a real-time human cytomegalovirus (HCMV) PCR caused by nucleotide variability within exon 4 of the major immediateearly (MIE) gene (3). For more than 6 years, we and other laboratories have routinely used an HCMV in-house realtime PCR assay with primers and probe different from those used by Lengerova et al. but amplifying a sequence also lo...
متن کاملExon 4 of the Human Cytomegalovirus (CMV) Major Immediate-Early Gene as a Target for CMV Real-Time PCR
Lengerova et al. recently published on the failure of a real-time human cytomegalovirus (HCMV) PCR caused by nucleotide variability within exon 4 of the major immediateearly (MIE) gene (3). For more than 6 years, we and other laboratories have routinely used an HCMV in-house realtime PCR assay with primers and probe different from those used by Lengerova et al. but amplifying a sequence also lo...
متن کاملExon 4 of the human cytomegalovirus (CMV) major immediate-early gene as a target for CMV real-time PCR.
Lengerova et al. recently published on the failure of a real-time human cytomegalovirus (HCMV) PCR caused by nucleotide variability within exon 4 of the major immediateearly (MIE) gene (3). For more than 6 years, we and other laboratories have routinely used an HCMV in-house realtime PCR assay with primers and probe different from those used by Lengerova et al. but amplifying a sequence also lo...
متن کاملDETECTION AND RESTRICTION ANALYSIS OF C YTOMEGALOVIRUS DNA PERSISTING IN HUMAN ATHEROSCLEROTIC PLAQUES USING POLYMERASE CHAIN REACTION
The polymerase chain reaction (PCR) as applied to detection of a foreign DNA in clinical specimens could provide a sensitive instrument for rapid detection of viral DNA persisting in tissues of patients suspected of latent infection. Human cytomegalovirus (HCMV) DNA was found in arterial plaques of patients with atherosclerotic lesions using a PCR assay with nested primer oligonucleotides ...
متن کاملEffect of interstrain variation on diagnostic DNA amplification of the cytomegalovirus major immediate-early gene region.
The immediate-early region exon 4 sequences of six clinical cytomegalovirus strains were determined and compared with those of laboratory strains AD169 and Towne. Of 407 codons in exon 4, 33 (8.1%) showed interstrain variation at the peptide level and 74 (18%) showed interstrain variation at the nucleotide level. Variation occurred sporadically throughout the exon, and no grouping of strains wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2007