Comparison of different systems of vectorcardiography.
نویسندگان
چکیده
It is usual for various investigators to use their own system of vectorcardiography. Such a system is characterized by the place of the electrodes and the way in which the vectorcardiogram is deduced from the potential differences obtained. At present the system according to Duchosal and Sulzer (1949) and the one proposed by Wilson et al. (1947) are much in use. The equilateral tetrahedron proposed by the latter is a generalization of the equilateral triangle of Einthoven et al. (1913). In addition the present authors have proposed and used another fundamentally different method, based on the following line of thought. By this method, the principle of which is physically well founded (1946), the vectorcardiogram may be deduced from three potential differences. That is to say, if the electromotive force of the heart may be considered as that of a single dipole, there will be a linear relation between each potential difference Vp-Vq and the three orthogonal components X, Y, Z of the heart vector:
منابع مشابه
Comparison of Four Orthogonal Systems of Vectorcardiography BY PAUL
Four orthogonal systems of vectorcardiography that are considered to be more accurate than th(tetrahedron and cube systems were compared. In a large majority of subjects the records made with each of the 4 systems were similar. However, in 5 of 60 subjects in whom the Z lead was studied, dissimilarities were found that were considered to be significant. The possible reasons for these dissimilar...
متن کاملComparison of Four Orthogonal Systems
Four orthogonal systems of vectorcardiography that are considered to be more accurate than th(tetrahedron and cube systems were compared. In a large majority of subjects the records made with each of the 4 systems were similar. However, in 5 of 60 subjects in whom the Z lead was studied, dissimilarities were found that were considered to be significant. The possible reasons for these dissimilar...
متن کاملCompensation Strategies for Shunt Active Power Filter in Single- and Three-Phase Systems: Different Formulation, Comparison and Evaluation
متن کامل
Langner , Okada , Moore , and ) Fies Sponge
Four orthogonal systems of vectorcardiography that are considered to be more accurate than th(tetrahedron and cube systems were compared. In a large majority of subjects the records made with each of the 4 systems were similar. However, in 5 of 60 subjects in whom the Z lead was studied, dissimilarities were found that were considered to be significant. The possible reasons for these dissimilar...
متن کاملComparison of Optimized PSS Using Three Different Methods for Single and Multi-Machines Systems
Oscillations of power systems cause instability in power networks. Power system stabilizer (PSS) is used as a conventional method to damp these oscillations . Finding the optimized gain of PSS is one of the major problems in power system stability issue. In this paper, single machine connected to an infinite bus and 10-machines 39-bus network are considered for study. it's shown that finding th...
متن کاملA Survey of Concurrency Control Algorithms in the Operating Systems
Concurrency control is one of the important problems in operation systems. Various studies have been reported to present different algorithms to address this problem, although a few attempts have been made to represent an overall view of the characteristics of these algorithms and comparison of their capabilities to each other. This paper presents a survey of the current methods for controlling...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 14 3 شماره
صفحات -
تاریخ انتشار 1952