Real-time optical coherence tomography of the anterior segment at 1310 nm.

نویسندگان

  • S Radhakrishnan
  • A M Rollins
  • J E Roth
  • S Yazdanfar
  • V Westphal
  • D S Bardenstein
  • J A Izatt
چکیده

BACKGROUND Recent advances in high-speed scanning technology have enabled a new generation of optical coherence tomographic (OCT) systems to perform imaging at video rate. Here, a handheld OCT probe capable of imaging the anterior segment of the eye at high frame rates is demonstrated for the first time. OBJECTIVE To demonstrate real-time OCT imaging of anterior segment structures. DESIGN Survey of anterior segment structures in normal human subjects. SETTING Laboratory. MAIN OUTCOME MEASURES Achieving real-time imaging of the anterior segment, satisfactory image quality, and convenience of a handheld probe. RESULTS Optical coherence tomographic imaging of the anterior segment of the eyes of human subjects was performed using 1310-nm wavelength light with an image rate of 8 frames per second. Imaging trials demonstrated clear resolution of corneal epithelium and stroma, sclerocorneal junction, sclera, iris pigment epithelium and stroma, and anterior lens capsule. The anterior chamber angle was clearly visualized. Limited imaging of the ciliary body was performed. Real-time imaging of pupillary constriction in response to light stimulus was also performed. CONCLUSION High-speed OCT at 1310-nm wavelength is a potentially useful technique for noninvasive assessment of anterior segment structures. CLINICAL RELEVANCE Our results suggest that real-time OCT has potential applications in glaucoma evaluation and refractive surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second

An ultrafast frequency domain optical coherence tomography system was developed at A-scan rates between 2.5 and 10 MHz, a B-scan rate of 4 or 8 kHz, and volume-rates between 12 and 41 volumes/second. In the case of the worst duty ratio of 10%, the averaged A-scan rate was 1 MHz. Two optical demultiplexers at a center wavelength of 1310 nm were used for linear-k spectral dispersion and simultane...

متن کامل

Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology

Purpose. Application of anterior segment optical coherence (AS-OCT) in pediatric ophthalmology. Methods. Retrospective clinical study case series of 26 eyes of 19 pediatric patients throughout a 21-month period, presenting anterior segment pathologies, were submitted to AS-OCT examination (OCT Visante, 1310 nm, Zeiss), noncontact technique, no sedation requirement. Results. AS-OCT images were o...

متن کامل

Anterior segment optical coherence tomography for evaluation of changes in anterior chamber angle and depth after intraocular lens implantation in eyes with glaucoma.

PURPOSE To examine anterior chamber depth (ACD) and anterior chamber angle (ACA) in patients with glaucoma after cataract extraction with an anterior optical coherence tomography (OCT) system. METHODS A new commercially available 1310 nm infrared light anterior segment OCT system was used for anterior chamber evaluation. Sixty patients (n=20 with primary open angle glaucoma [POAG], n=20 with ...

متن کامل

Pupil Tracking for Real-Time Motion Corrected Anterior Segment Optical Coherence Tomography

Volumetric acquisition with anterior segment optical coherence tomography (ASOCT) is necessary to obtain accurate representations of the tissue structure and to account for asymmetries of the anterior eye anatomy. Additionally, recent interest in imaging of anterior segment vasculature and aqueous humor flow resulted in application of OCT angiography techniques to generate en face and 3D micro-...

متن کامل

Anterior Chamber Angle Evaluation with Fourier-Domain Optical Coherence Tomography

New advances in anterior segment optical coherence tomography (OCT) technology development allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Fourier-domain (FD) OCT instruments working at 840 nm can reliably identify fine angle structures such as the Schwalbe's line. This paper demonstrates quantitative angle assessment with 840 nm FD-OCT and provides ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 119 8  شماره 

صفحات  -

تاریخ انتشار 2001