Computed Tomography Imaging of Primary Lung Cancer in Mice Using a Liposomal-Iodinated Contrast Agent

نویسندگان

  • Cristian T. Badea
  • Khannan K. Athreya
  • Gabriela Espinosa
  • Darin Clark
  • A. Paiman Ghafoori
  • Yifan Li
  • David G. Kirsch
  • G. Allan Johnson
  • Ananth Annapragada
  • Ketan B. Ghaghada
چکیده

PURPOSE To investigate the utility of a liposomal-iodinated nanoparticle contrast agent and computed tomography (CT) imaging for characterization of primary nodules in genetically engineered mouse models of non-small cell lung cancer. METHODS Primary lung cancers with mutations in K-ras alone (Kras(LA1)) or in combination with p53 (LSL-Kras(G12D);p53(FL/FL)) were generated. A liposomal-iodine contrast agent containing 120 mg Iodine/mL was administered systemically at a dose of 16 µl/gm body weight. Longitudinal micro-CT imaging with cardio-respiratory gating was performed pre-contrast and at 0 hr, day 3, and day 7 post-contrast administration. CT-derived nodule sizes were used to assess tumor growth. Signal attenuation was measured in individual nodules to study dynamic enhancement of lung nodules. RESULTS A good correlation was seen between volume and diameter-based assessment of nodules (R(2)>0.8) for both lung cancer models. The LSL-Kras(G12D);p53(FL/FL) model showed rapid growth as demonstrated by systemically higher volume changes compared to the lung nodules in Kras(LA1) mice (p<0.05). Early phase imaging using the nanoparticle contrast agent enabled visualization of nodule blood supply. Delayed-phase imaging demonstrated significant differential signal enhancement in the lung nodules of LSL-Kras(G12D);p53(FL/FL) mice compared to nodules in Kras(LA1) mice (p<0.05) indicating higher uptake and accumulation of the nanoparticle contrast agent in rapidly growing nodules. CONCLUSIONS The nanoparticle iodinated contrast agent enabled visualization of blood supply to the nodules during the early-phase imaging. Delayed-phase imaging enabled characterization of slow growing and rapidly growing nodules based on signal enhancement. The use of this agent could facilitate early detection and diagnosis of pulmonary lesions as well as have implications on treatment response and monitoring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro-CT imaging of breast tumors in rodents using a liposomal, nanoparticle contrast agent

A long circulating liposomal, nanoscale blood pool agent encapsulating traditional iodinated contrast agent (65 mg I/mL) was used for micro-computed tomography (CT) imaging of rats implanted with R3230AC mammary carcinoma. Three-dimensional vascular architecture of tumors was imaged at 100-micron isotropic resolution. The image data showed good qualitative correlation with pathologic findings. ...

متن کامل

A liposomal nanoscale contrast agent for preclinical CT in mice.

OBJECTIVE The goal of this study was to determine if an iodinated, liposomal contrast agent could be used for high-resolution, micro-CT of low-contrast, small-size vessels in a murine model. MATERIALS AND METHODS A second-generation, liposomal blood pool contrast agent encapsulating a high concentration of iodine (83-105 mg I/mL) was evaluated. A total of five mice weighing between 20 and 28 ...

متن کامل

Multi-Modal Imaging in a Mouse Model of Orthotopic Lung Cancer

BACKGROUND Investigation of CF800, a novel PEGylated nano-liposomal imaging agent containing indocyanine green (ICG) and iohexol, for real-time near infrared (NIR) fluorescence and computed tomography (CT) image-guided surgery in an orthotopic lung cancer model in nude mice. METHODS CF800 was intravenously administered into 13 mice bearing the H460 orthotopic human lung cancer. At 48 h post-i...

متن کامل

Time-course characterization of the computed tomography contrast enhancement of an iodinated blood-pool contrast agent in mice using a volumetric flat-panel equipped computed tomography scanner.

OBJECTIVE The objective of this study was to determine the time-course of computed tomography (CT) contrast enhancement of an iodinated blood-pool contrast agent. METHODS Five C57BL/6 mice were anesthetized, imaged at baseline, and given an iodinated blood-pool contrast agent. Micro-CT scans were acquired at 0, 0.25, 0.5, 1, 2, 4, 8, and 24 hours after injection. The mean CT number was determ...

متن کامل

A Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.

 Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012