Acceleration and motion-correction techniques for high-resolution intravascular MRI.

نویسندگان

  • Shashank Sathyanarayana Hegde
  • Yi Zhang
  • Paul A Bottomley
چکیده

PURPOSE High-resolution intravascular (IV) MRI is susceptible to degradation from physiological motion and requires high frame-rates for true endoscopy. Traditional cardiac-gating techniques compromise efficiency by reducing the effective scan rate. Here we test whether compressed sensing (CS) reconstruction and ungated motion-compensation using projection shifting, could provide faster motion-suppressed, IVMRI. THEORY AND METHODS CS reconstruction is developed for undersampled Cartesian and radial imaging using a new IVMRI-specific cost function to effectively increase imaging speed. A new motion correction method is presented wherein individual IVMRI projections are shifted based on the IVMRI detector's intrinsic amplitude and phase properties. The methods are tested at 3 Tesla (T) in fruit, human vessel specimens, and a rabbit aorta in vivo. Images are compared using structural-similarity and "spokal variation" indices. RESULTS Although some residual artifacts persisted, CS acceleration and radial motion compensation strategies reduced motion artifact in vitro and in vivo, allowing effective accelerations of up to eight-fold at 200-300 µm resolution. CONCLUSION The 3T IVMRI detectors are well-suited to CS and motion correction strategies based on their intrinsic radially-sparse sensitivity profiles and high signal-to-noise ratios.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated, motion-corrected high-resolution intravascular MRI at 3T.

Audience: Interventionalists, and those interested in atherosclerosis and intravascular MR imaging. Purpose. Current speeds for intravascular (IV) MRI and MRI endoscopy are limited to ~2frames/s at 3T, rendering high-resolution (~100μm) images susceptible to degradation by physiological motion on the order of mm/ms. Here, using projection reconstruction we: (A) reduce sensitivity to motion from...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

High-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition

High-resolution diffusion MRI can provide the ability to resolve small brain structures, enabling investigations of detailed white matter architecture. A major challenge for in vivo high-resolution diffusion MRI is the low signal-to-noise ratio. In this work, we combine two highly compatible methods, ultra-high field and three-dimensional multi-slab acquisition to improve the SNR of high-resolu...

متن کامل

Retrospective Motion Correction for Cardiovascular and Body Imaging

Clinical MRI protocols are the result of a trade-off between spatial and/or temporal resolution, signal-to-noise ratio (SNR), contrast and acquisition duration. The latter is often the limiting factor in MRI of moving organs such as in cardiovascular and body imaging. This is because clinical protocols most often deal with motion through cardiac synchronization (e.g. using the ECG) and patient ...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 74 2  شماره 

صفحات  -

تاریخ انتشار 2015