Fetal blood flow measured using phase contrast MRI-comparison of image quality and flow volume at 1.5T with 3.0T
نویسندگان
چکیده
Background Ultrasound is commonly used for the antenatal assessment of a fetus and it can provide functional and haemodynamic data in addition to anatomical details. The accuracy of the former is dependant on angle of insonation, maternal habitus and fetal position. Phase contrast cardiovascular magnetic resonance (PC CMR) has emerged as a clinical tool for blood flow quantification but its use in the foetus has been hampered by the need for gating with the fetal heart beat. Previously described metric optimized gating (MOG) technique has been successfully used to measure fetal blood flow in late gestation foetuses on a 1.5T MRI magnet. However, there is increasing interest in performing foetal cardiac imaging using 3.0T MRI. We describe our pilot data of fetal blood flow measured in 3.0T MRI using MOG technique.
منابع مشابه
MR imaging of the fetal brain at 1.5T and 3.0T field strengths: comparing specific absorption rate (SAR) and image quality.
OBJECTIVES Our two objectives were to evaluate the feasibility of fetal brain magnetic resonance imaging (MRI) using a fast spin echo sequence at 3.0T field strength with low radio frequency (rf) energy deposition (as measured by specific absorption rate: SAR) and to compare image quality, tissue contrast and conspicuity between 1.5T and 3.0T MRI. METHODS T2 weighted images of the fetal brain...
متن کاملEvaluation of diffuse myocardial fibrosis using contrast-enhanced look-locker cardiac MRI and its relation with cardiac function in dilated cardiomyopathy: comparison between 1.5T and 3T
Background Cardiac MRI is useful for evaluation of severity and prognosis of DCM. This can render myocardial scarring in delayed contrast-enhanced MRI, but the scarring is observed only in 30%-40% of DCM cases presenting with congestive heart failure. Because of its binary contrast between the normal myocardium and scarring, delayed contrasenhanced MRI may fail to detect the diffuse myocardial ...
متن کامل[Vessel contrast and saturation effect at three Tesla in three-dimensional time of flight magnetic resonance angiography].
The purpose of this study was to clarify the effects of the increased field strength of 1.5T vs. 3.0T on blood vessel contrast and saturation in 3D time of flight MR angiography. Vessel contrast and saturation effect were evaluated for various flow velocities and flip angles using a steady-state flow phantom. The results showed increased vessel contrast and decreased saturation of blood on 3.0T...
متن کاملOptimization and Comparison of Non-Contrast-Enhanced Inflow-Sensitive Inversion Recovery bSSFP for Renal and Mesenteric MRA at 1.5T and 3.0T
Purpose: Patients with kidney disease are most likely to need renal imaging, yet the standard technique of contrast-enhanced MR angiography with gadolinium may be contraindicated in these patients. This disadvantage and others demonstrate a need to explore non-contrast-enhanced MRA methods [1]. We evaluated one non-contrast enhanced MRI technique which has shown promising results: respiratory-g...
متن کاملCEMRA in neonatal and pediatric congenital vascular diseases at 1.5T and 3.0T: comparison of an intravascular contrast agent (Gadofosveset) with an extracellular agent (Gadopentetate Dimeglumine)
Methods Twenty-eight pediatric patients with CCHD underwent CEMRA at 3.0T (n=16) or at 1.5T (n=12). Sixteen patients were imaged with gadofosveset; 9 at 3.0T (age 1.00 ± 1.58 months; weight 2.38 ± 1.13 kg) and 7 at 1.5T (age 8.00 ± 7.83 months; weight 5.06 ± 3.09 kg). Twelve patients were imaged with gadopentetate; 7 at 3.0T (age 1.00 ± 1.41 months; weight 3.02 ± 1.59 kg) and 5 at 1.5T (age 6.6...