Bactericidal effects of acidic electrolyzed water on the dental unit waterline.

نویسندگان

  • Shinya Kohno
  • Toshitsugu Kawata
  • Masato Kaku
  • Tadashi Fuita
  • Keisuke Tsutsui
  • Junji Ohtani
  • Kaoru Tenjo
  • Masahide Motokawa
  • Yuiko Tohma
  • Mao Shigekawa
  • Hiroko Kamata
  • Kazuo Tanne
چکیده

Many studies have been conducted in the United States regarding the microbial contamination of dental unit waterline, but not in Japan. Recently, acidic electrolyzed water has been used in the medical and dental fields. In this study, we investigated the bactericidal effects of the temporary inflow of acidic electrolyzed water on microbial contamination of the dental unit waterline. First, in order to observe the daily bacterial contamination of the dental unit waterline, water samples were collected at the end of handpieces and three-way syringes before the inflow of acidic electrolyzed water. They were cultured to detect viable bacteria. Later, the inflow of acidic electrolyzed water was conducted through the piping box of the dental unit. Before starting operation on next day, water samples were collected and cultured, as described above. The mean viable bacteria count was 910 -/+ 190 CFU/ml at the end of handpieces, and 521 -/+ 116 CFU/ml at the end of three-way syringes before the inflow of acidic electrolyzed water. However, bacteria were detected in only small numbers at the end of handpieces and three-way syringes on the next day. These results indicated that acidic electrolyzed water could be applied as an appropriate measure against bacterial contamination of the dental unit waterline.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial Control of Fresh Produce using Electrolyzed Water

The demand for fresh salad vegetables, such as iceberg lettuce, has increased worldwide in recent years. Numerous sanitizers have been examined for their effectiveness in killing or removing pathogenic bacteria on fresh produce. However, most of the sanitizers are made from the dilution of condensed solutions which involves some risk in handling and is troublesome. A sanitizer that is not produ...

متن کامل

Effectiveness of electrolyzed acidic water in killing Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes on the surfaces of tomatoes.

A study was conducted to evaluate the efficacy of electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water in killing Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes on the surfaces of spot-inoculated tomatoes. Inoculated tomatoes were sprayed with electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water (control) and rubbed by hand f...

متن کامل

Effect of rinsing alginate impressions using acidic electrolyzed water on dimensional change and deformation of stone models.

This study investigated the effect of rinsing alginate impressions using acidic electrolyzed water on the dimensional change and deformation of stone models. Two brands of alginate impression materials were used. The impressions were rinsed using tap water or acidic electrolyzed water with a pH of 2.3, an oxidation-reduction potential of 1,230 mV, and a residual chlorine concentration of 45.0 p...

متن کامل

The bactericidal effects of electrolyzed oxidizing water on bacterial strains involved in hospital infections.

The study is designed to investigate bactericidal actions of electrolyzed oxidizing water on hospital infections. Ten of the most common opportunistic pathogens are used for this study. Cultures are inoculated in 4.5 mL of electrolyzed oxidizing (EO) water or 4.5 mL of sterile deionized water (control), and incubated for 0, 0.5, and 5 min at room temperature. At the exposure time of 30 s the EO...

متن کامل

Bactericidal effect of electrolyzed neutral water on bacteria isolated from infected root canals.

OBJECTIVE The purposes of this study were to examine the time-related changes in pH, oxidation-reduction potential, and concentration of chlorine of electrolyzed neutral water and to evaluate the bactericidal effect of electrolyzed neutral water against bacteria from infected root canals. STUDY DESIGN Various properties of electrolyzed neutral water--pH value, oxidation-reduction potential, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of infectious diseases

دوره 57 2  شماره 

صفحات  -

تاریخ انتشار 2004