Dual fluorometric/colorimetric detection system for an automated random-access instrument utilizing standard polystyrene test tubes as precision cuvettes.

نویسندگان

  • M E Astill
  • L R Johnson
  • G H Thorne
  • G H Krauth
  • R E Smith
  • R W Smith
  • T R Witty
چکیده

To attain the optical precision necessary to precisely quantify fluorescent or colorimetric signals, analytical systems have typically included quality-controlled cuvettes, flow cells, or dual-beam reference systems. We describe a system where a fluorescence or transmittance signal is quantified in single, standard, 12-mm-diameter polystyrene test tubes. Tube-to-tube variation is minimized by referencing the primary signal to a second reference signal. The tube is carefully oriented within a positioner that allows for the precise placement of the tube within a light path 7.6 mm in diameter. The detection system allows for use of either four pairs of fluorescence excitation/emission wavelengths or eight transmittance wavelengths, which are selected by using specific interference filters. The impact of temperature, tube imperfections, surface flaws, and distortions is minimized by using a reference ratio. Fluorescence is measured with an orthogonal photomultiplier tube, and transmittance with a photodiode; both are illuminated with an ordinary long-life tungsten-halogen lamp. This system is used with the Becton Dickinson AFFINITY system, an automated random-access analyzer with analyte-specific unit-package reagents. The polystyrene tube of the reagent package, which has an antibody-absorbed surface, serves as both the cuvette and the separation medium. Use of the reference ratio method reduces intertube imprecision of fluorometric or transmittance signals, for more precise quantification of various analytes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Dual colorimetric and Fluorometric Anion Sensor Based on Polymerizable 1, 8-Naphthalimide Dye

A new polymerizable fluorescent sensor based on the photoinduced electron transfer PET for the selective determination of fluoride ions in DMF solutions has been synthesized. The sensing system was prepared by incorporating 4-Amino-1,8-naphthalimide derivatives containing thiourea side chain at the amino moiety AFTN as a neutral F- selective flourophore and was characterized by use of the DSC, ...

متن کامل

An automatic test case generator for evaluating implementation of access control policies

One of the main requirements for providing software security is the enforcement of access control policies which aim to protect resources of the system against unauthorized accesses. Any error in the implementation of such policies may lead to undesirable outcomes. For testing the implementation of access control policies, it is preferred to use automated methods which are faster and more relia...

متن کامل

Laboratory evaluation of the COBAS MIRA S random access analyser

The random access analyser COBAS MIRA S (Roche Diagnostics) was evaluated for two months. The instrument is a computer-controlled discrete analyser which can be run in a combination profile and single test mode. This instrument has special features, including an automatic cuvette segment changer, a reagent rack cooling system, an external keyboard and monitor, as well as a bar-code facility for...

متن کامل

استانده کردن و اصلاح روش فلوئورومتری برای اندازه گیری هیستامین خون تام

Histamine (Hm), formed during decarboxylation of L-histidine by the action of L-histidine decarboxylase, a pyridoxal phophate dependent enzyme, is one of the main mediator in such allergic diseases as asthma, urticaria and hay fever. Hence Hm assay can be used as a diagnostic tool in these disorders. There are three main methods for Hm assaying: (1) radioenzymatic (2) radioimmunoassay (RIA) ...

متن کامل

Carbon Nanodots as Dual-Mode Nanosensors for Selective Detection of Hydrogen Peroxide

Hydrogen peroxide (H2O2) is an important product of oxidase-based enzymatic reactions, such as glucose/glucose oxidase (GOD) reaction. Therefore, the probing of generated H2O2 for achieving the detection of various carbohydrates and their oxidases is very significative. Herein, we report one kind of dual-emission carbon nanodots (CDs) that can serve as novel dual-mode nanosensors with both fluo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 9  شماره 

صفحات  -

تاریخ انتشار 1987