Orientation tuning of the transient-stereopsis system
نویسندگان
چکیده
Stereo-perception appears to be mediated by at least two systems: a transient system that processes stimuli presented briefly and a sustained one that processes stimuli presented for longer durations. In this paper we investigated the tuning of the transient-stereopsis system to stimulus orientation. Narrowband-gabor targets with a constant envelope size (Gaussian standard deviation of 1 degree) were presented for brief (140 ms) durations at large (from 4 to 8 degrees) disparities. The results were as follows: (1) while observers could extract depth from orthogonally-oriented gabors at above chance levels, their performance was worse than that with gabors of matched orientation; (2) varying the relative contrasts of the two orthogonally oriented gabors of the same spatial frequency resulted in a reduction in performance; (3) varying the relative spatial frequencies of the orthogonally-oriented gabors impaired performance, relative to that for matched frequencies; and (4) varying the relative contrasts of orthogonal gabors that were at different spatial frequencies could improve performance. These results indicate that transient stereo-performance in the orthogonal condition was not mediated by the channels that extracted depth in either the horizontal- or vertically-matched gabor conditions. This apparent lack of orientation tuning is indicative of a second-order pathway. That this performance was mediated by a binocular, as opposed to a monocular channel, is supported by the finding that performance decreased as the contrast of one of the gabors was reduced. The finding that performance with orthogonal gabors of unmatched spatial frequency (0.5 and 4 cpd) could be improved by varying their relative contrasts suggests that the binocular spatial-frequency tuning exhibited by this channel is broadband in nature. Finally, the observation that lowering the contrast of either the high or low spatial-frequency gabor improved performance suggests the presence of at least two broadband channels: one with its peak sensitivity at a low and the other at a high spatial-frequency.
منابع مشابه
Envelope size tuning for stereo-depth perception of small and large disparities
Stereopsis is the sense of depth derived from binocular disparities that are formed between targets that are matched between the two retinal images. Binocular matches for sustained stereopsis are based on similarity of orientation, spatial frequency and contrast of the two retinal images whereas matches for transient stereopsis depend on these parameters to a very limited extent. In this invest...
متن کاملSpatial-frequency and contrast tuning of the transient-stereopsis system
The tuning of the transient-stereopsis system to luminance contrast and spatial-frequency (SF) was investigated with narrow-band gabor targets with a constant sigma of 1 degree. They were presented for brief (140 ms) durations and subtended a large (6 degrees) disparity. When dichoptic gabor stimuli were matched in SF (0-5 cpd), transient stereo performance was either uniform across SF or great...
متن کاملThe transient nature of 2nd-order stereopsis
There are currently two competing dichotomies used to describe how local stereoscopic information is processed by the human visual system. The first is in terms of the type of the spatial filtering operations used to extract relevant image features prior to stereoscopic analysis (i.e. 1st- vs 2nd-order stereo; [Hess, R. F., & Wilcox, L. M. (1994). Linear and non-linear filtering in stereopsis. ...
متن کاملApplication of an Additive Self-tuning Controller for Static Synchronous Series Compensator for Damping of Sub-synchronous Resonance Oscillations
In this paper, an additive self-tuning (ST) control scheme is presented for a static synchronous series compensator (SSSC) to improve performance of conventional PI control system for damping sub-synchronous resonance (SSR) oscillations. The active and reactve series compensation are provided by a three-level 24-pulse SSSC and fixed capacitor. The proposed ST controller consists of a pole shift...
متن کاملTransient Stability Enhancement in Microgrids Including Inverter Interfaced Distributed Generations
With increasing the presence of Microgrids (MGs) in the power systems, investigating the MG stability during transient faults is necessary. This study investigates the transient stability analysis of a MG supplied by multiple inverter interfaced distributed generations (IIDGs) during fault. The transient stability of a MG is highly depends on the IIDGs control strategy. A MG, simulated on Matla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 39 شماره
صفحات -
تاریخ انتشار 1999