Adaptive probabilistic approach for selecting tumour knee prosthesis
نویسندگان
چکیده
Tumour knee prostheses reconstruct bone gaps, left after resecting the tumour affected tissues, in limb salvage surgeries of bone cancer patients. They typically comprise of 6-12 different components chosen from a family of components that are manufactured in discrete variations (intended to cater to a wide range of patient conditions including gender, tumour position, leg (left/right), and resection length). These variations generate numerous combinations and selecting a correct set of components from a family of 100 or more total components has made the process difficult for a given patient. This article describes an adaptive probabilistic approach developed for selection of tumour knee prosthesis components, driven by geometric details. These details were extracted from the 3D virtual anatomical model, reconstructed from set of CT scan images of patients. The selection was performed in two steps. First, the grossly undersized and oversized components were eliminated. Then the geometric details of components were mapped, with the measured anatomical parameters of the patient, to form a fuzzy-logic based decision tree. This was based on pre-defined rules compiled from surgeons' experience. A set of measures (geometric difference, bone curvature, knee centre shift, and reconstruction length) were used to evaluate the selected prosthesis components. Evaluation was based on their suitability with respect to the patient's anatomy, and classified with a qualitative tag: ‘most suitable’, ‘probably suitable’, or ‘not suitable’. A case study of distal femur replacement is presented to explain the proposed methodology. This approach eliminates the risk of over and under sizing of the prosthesis components and reduces the average inventory to be maintained for each patient.
منابع مشابه
Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach
Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...
متن کاملPassive Controller Design for Swing Phase of a Single Axis Above-Knee Prosthesis
In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...
متن کاملThe early results of joint-sparing proximal tibial replacement for primary bone tumours, using extracortical plate fixation.
This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into th...
متن کاملDirect exchange endoprosthetic reconstruction with tumour prosthesis for periprosthetic knee infection associated with segmental bone defects
Revision knee arthroplasty for infection poses a treatment challenge. The presence of massive osteolysis limits the treatment options in this cohort. Controversy exists in the management of these patients. Direct exchange arthroplasty has provided good results in the presence of infection, but whether this is appropriate in the presence of massive bone defects associated with the infection is u...
متن کاملDynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject
The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Comput. Sci. Inf. Syst.
دوره 10 شماره
صفحات -
تاریخ انتشار 2013