Longevity of implantable cardioverter-defibrillators for cardiac resynchronization therapy in current clinical practice: an analysis according to influencing factors, device generation, and manufacturer
نویسندگان
چکیده
AIMS Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. METHODS AND RESULTS We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. CONCLUSION The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers.
منابع مشابه
Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.
AIMS Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. METHODS AND RESULTS All...
متن کاملBattery drain in daily practice and medium-term projections on longevity of cardioverter-defibrillators: an analysis from a remote monitoring database
AIMS The longevity of generators is a crucial determinant of the cost-effectiveness of therapy with implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We evaluated the trend of device-measured residual battery capacity and longevity projections over 5-year follow-up. We also investigated possible factors associated with battery drain. ...
متن کاملIncidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
متن کاملLongevity of implantable cardioverter defibrillators: a comparison among manufacturers and over time
AIMS Longevity of implantable cardioverter defibrillators (ICDs) is crucial for patients and healthcare systems as replacements impact on infection rates and cost-effectiveness. Aim was to determine longevity using very large databases of two teaching hospitals with a high number of replacements and a rather homogeneous distribution among manufacturers. METHODS AND RESULTS The study populatio...
متن کاملThe economic impact of battery longevity in implantable cardioverter-defibrillators for cardiac resynchronization therapy: the hospital and healthcare system perspectives
Aims Patients receiving cardiac resynchronization therapy defibrillators (CRT-Ds) are likely to undergo one or more device replacements, mainly for battery depletion. We assessed the economic impact of battery depletion on the overall cost of CRT-D treatment from the perspectives of the healthcare system and the hospital. We also compared devices of different generations and from different manu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2015