Designing and Fabricatin&licro-PressureSensors for Spiral Chff Electrodes
نویسنده
چکیده
Ab~fluct-Cuff electrode an important component of neural prostheseq has been developed and improved in many research groups It is well known that cuff electrode has the potential hazard of causing nerve in& by compression. The goal of this study is to design a spiral cuff electrode witkmbedded micr &pressure sensor by using g i c r 0-glectr @mechanical system (MEMS) technologies. The pressure sensor4 serving as an on-line well-being monitor,can prevent Lcbemic necrosis of a nerve from excessive pressure We adopted capacitive mechanism as the basic configuration, because of its high sensitivity and good noise resistance. Tbesensor was designed and simulated witlfkite element analyses.
منابع مشابه
An overview of cochlear implant electrode array designs
Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode arra...
متن کاملWhole Nerve Recordings with the Spiral Nerve Cuff Electrode
The feasibility of whole nerve recordings from the hypoglossal (HG) nerve is demonstrated in acute cats using the spiral nerve cuff electrode. A good contact between the nerve and the electrodes, provided by the spiral nerve cuff due to its self-coiling property, should improve the signal-tonoise ratio. An instrumentation amplifier with very low input noise characteristics is also utilized. The...
متن کاملCochlear implant simulator with independent representation of the full spiral ganglion.
In cochlear implant simulation with vocoders, narrow-band carriers deliver the envelopes from each analysis band to the cochlear positions of the simulated electrodes. However, this approach does not faithfully represent the continuous nature of the spiral ganglion. The proposed "SPIRAL" vocoder simulates current spread by mixing all envelopes across many tonal carriers. SPIRAL demonstrated tha...
متن کاملComparative study of cochlear damage with three perimodiolar electrode designs.
OBJECTIVE To describe intracochlear insertion trauma caused by three perimodiolar cochlear implant electrodes. STUDY DESIGN Descriptive histological study of 15 human cadaver temporal bones. METHODS Fifteen cadaver temporal bones underwent surface preparation and were implanted with one of the following perimodiolar electrode arrays: Combi 40+PM (MedEl Corporation), HiFocus II (Advanced Bio...
متن کاملHistopathology Following Electrode Insertion and Chronic Electrical Stimulation
We have examined a number of safety issues associated with cochlear implants. This work has been primarily designed to evaluate the histopathological effects of intracochlear electrode implantation and chronic electrical stimUlation. The results of these studies may be summarized as follows: 1) The insertion of the banded free-fit scala tympani array into human cadaver temporal bones produces m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004