Effect of the detector dead-time uncertainty on the analytical result of minor elements in low-alloy steel by isotope dilution/ICP sector field mass spectrometry.

نویسندگان

  • Naoko Nonose
  • Akiharu Hioki
  • Koichi Chiba
چکیده

In the present study the effects of the detector dead-time and its uncertainties on the accuracy and uncertainty of isotope dilution mass spectrometry (IDMS) were considered through an interlaboratory study on the analysis of low-alloy steel by using an ICP-sector field mass spectrometer. Also, an optimized mixing ratio of the sample and the spike to obtain highly precise results was theoretically and experimentally investigated. The detector dead-time used in the interlaboratory study showed a negative value. However, it less affected the trueness of the analytical result if the dead-time correction for the measured isotope ratio was done properly. As many researchers have pointed out, the detector dead-time showed a clear mass dependence. Therefore, it is desirable to check the dead-time in every target element by using assay standards or isotopic standards, which would lead to an accurate result even if the detector dead-time is a negative value. On the other hand, the effect of the uncertainty of the detector dead-time can be minimized when both isotope ratios and ICP-MS signals of the [sample + spike] blend in IDMS are equal to those of [spike + assay standard] in reverse IDMS. From standpoints of error magnification theory and the precision of the isotope ratio measurement, an optimized isotope ratio of the sample-spike blend would be 1.0 for an element with a large difference in ten times and more between the atomic fractions of two isotopes used for IDMS. In the case of an element with no significant difference between the atomic fractions of two isotopes, an optimized isotope ratio can be calculated by a formula expressed as a function of the atomic fractions of the sample and the spike as well as the signal of ICP-MS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch

A new method for the measurement of calcium isotope ratios and total calcium, using a double focusing sector field inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a shielded torch, is presented. The method was applied for the measurement of the Ca/Ca, Ca/Ca and Ca/Ca ratios and total calcium by isotope dilution in urine samples from two different nutritional exper...

متن کامل

Laser defocusing effects on laser ablation inductively coupled plasma-atomic emission spectrometry: different ablation interactions between the laser and low-alloy steel, Fe pellets, and a pond sediment pellet.

The ablation interaction between a laser and solid samples, which affects the analytical performance for laser ablation inductively coupled plasma atomic emission spectrometry (LA-ICP-AES), was studied. The emission intensities of elements observed by LA-ICP-AES (LA-ICP-AES element signal intensities) for different solid samples were measured under different laser defocusing conditions with a f...

متن کامل

Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS

This application note describes the quantification of cadmium, chromium, lead and mercury in plastic materials by external calibration using the Agilent 7500ce ICP-MS system equipped with an Octopole Reaction System (ORS). Isotope dilution analysis with ICP-MS was used as a confirmatory technique. Good agreement of the results obtained by the two calibration approaches was achieved. The sample ...

متن کامل

A Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application

An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...

متن کامل

Reduction of UH formation for U/U isotope ratio measurements at ultratrace level in double focusing sector field ICP-MS using D2O as solvent

The main factors affecting the accurate and precise determination of U using ICP-MS are instrumental background, the isobaric interference of UH molecular ion on U analyte ions, and the presence of U and U peak tails. An optimized analytical method for attenuating the influence of these factors on uranium isotope ratio measurements at ultratrace level of environmental samples has been developed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 30 9  شماره 

صفحات  -

تاریخ انتشار 2014