An automated method for serum calcium utilizing ethylene diamine tetraacetic acid.

نویسنده

  • R G Burr
چکیده

A FUNDAMENTAL DIFFICULTY in estimating calcium in serum by photometry arises from the fact that the normal range is narrow relative to the concentration of calcium. In the cases of sodium and chloride which also possess narrow normal ranges, the automation problem has been approached in two different ways. For sodium the Technicon Flame Photometer incorporates an electrical range expander. In the Technicon N3a methodology for serum chloride the reagent contains mercuric nitrate which removes a certain amount of chloride from the reaction so that the calibration curve does not pass through the origin. In the present method, a similar effect is achieved for serum calcium by the addition of ethylene diamine tetraacetic acid (EDTA) to one of the reagents. Glyoxal-bis-(2-hydroxyanil) (GBHA) was used by Skerry in the estimation of calcium in serum by titration with EDTA (1). Mager and Farese (2) used it in the direct photometric analysis of serum calcium, a method which was adapted to the AutoAnalyzer by Farese et al (3). In the work reported here, a number of parameters have been studied. The method has been modified by the introduction of a dialysis step and by the use of an increased concentration of GBHA. A modified solvent is employed and EDTA has been incorporated into the buffer. GBHA

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation and Characterization of Thermophilic Alkaline Proteases Resistant to Sodium Dodecyl Sulfate and Ethylene Diamine Tetraacetic Acid from Bacillus sp. GUS1

Thermophilic Bacillus sp. GUS1, isolated from  a soil  sample obtained from citrus garden, produced at least three proteases as detected by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and zymogram analysis. The enzymes were stable in the alkaline pH range (8.0-12.0), with the optimum temperature and pH range of the proteases being 70ºC and 6.0-12.0, respectively. All th...

متن کامل

Automated calmagite compleximetric measurement of magnesium in serum, with sequential addition of EDTA to eliminate endogenous interference.

We describe an automated method for magnesium assay, for use with the Cobas-Bio centrifugal analyzer. Magnesium is reacted with calmagite, a dye, and the absorbance of the magnesium-dye complex at 520 nm is measured. EDTA is then added to break up the complex and the absorbance at 520 nm is re-measured to correct for sample color and turbidity. Including ethylene glycol bis(beta-aminoethyl ethe...

متن کامل

Proline metabolism in response to nitrogen deficiency in French Bean plants (<Emphasis Type="Italic">Phaseolus vulgaris</Emphasis> L. cv Strike)

The objective of the present work was to determine the impact of nitrogen deficiency on proline metabolism in French Bean plants (Phaseolus vulgaris L. cv. Strike). The nitrogen was applied to the nutrient solution in the form of NH4NO3 at 1.45 mM (N1), 2.90 mM (N2) and 5.80 mM (N3, optimal level). Our results indicate N deficiency is characterised by a decline in proline accumulation both in t...

متن کامل

Selective Response of Dopamine in the Presence of Ascorbic Acid and Uric Acid at Gold Nanoparticles and Multi-walled Carbon Nanotubes Grafted with Ethylene Diamine Tetraacetic Acid Modified Electrode

By grafting with ethylene diamine tetraacetic acid (EDTA), novel multi-walled carbon nanotube nano-composites (EDTA-MWCNTs) have been successfully prepared. The integration of gold nanoparticles (AuNPs) and novel functionalized matrix shows very promising applications in the fabrication of biosensors for sensitive detection of dopamine in the presence of ascorbic acid and uric acid with the com...

متن کامل

Compleximetric determination of calcium in pathological and physiological specimens.

Titrimetric estimation of calcium with disodium ethylene diamine tetra-acetate (E.D.T.A., sodium edetate), as performed on serum (Baron and Bell, 1957), cannot be applied directly to most other biological specimens because of their high concentration of phosphate. A high ratio of phosphate to calcium in the material titrated causes a drawnout and inaccurate endpoint. A rapid procedure for calci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 15 12  شماره 

صفحات  -

تاریخ انتشار 1969