Sources of variability in blood pressure measurement using the Dinamap PRO 100 automated oscillometric device.

نویسندگان

  • Joseph J Chang
  • Daniel Rabinowitz
  • Steven Shea
چکیده

The Dinamap automated oscillometric device (GE Medical Systems Information Technologies, Inc., Milwaukee, Wisconsin) for blood pressure measurement is widely employed in epidemiologic studies because it is easy to use and because it eliminates observer variability. In this study, the authors assessed the variability in observed blood pressures associated with use of the Dinamap monitor and estimated the contributions of various factors to that variability. In 60 volunteers (30 aged 23-35 years and 30 aged 54-82 years) from New York, New York, the authors obtained 30 simultaneous paired blood pressure measurements in both arms at 1-minute intervals, using three separate Dinamap PRO 100 devices allocated to arm and subject according to a balanced incomplete block design. Variability, defined as the between-arm difference in blood pressure measurements, was analyzed using a mixed-effects linear regression model. A total of 1,800 paired blood pressure measurements were obtained between September 2001 and June 2002. The mean ages of the two groups were 28.3 years (standard deviation, 4.0) and 71.7 years (standard deviation, 8.0). A diagnosis of hypertension was present in 53% of the older subjects and none of the younger subjects. Fifty percent of paired simultaneous blood pressure measurements obtained were in agreement within 4 mmHg for systolic blood pressure or within 3 mmHg for diastolic blood pressure. Residual variability, attributable to the intrinsic inaccuracy of the device, accounted for 64-82% of the total systolic and diastolic blood pressure variability. The majority of variability in blood pressure measurement was due to the device as used under the study conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of auscultatory and oscillometric blood pressures.

OBJECTIVE To study the differences in blood pressure readings between the auscultatory and oscillometric (Dinamap model 8100; Critikon, Tampa, Fla) methods. DESIGN Survey of 2 blood pressure instruments. SETTING Public schools. PARTICIPANTS Seven thousand two hundred eight schoolchildren aged 5 through 17 years. MAIN OUTCOME MEASURE Blood pressure levels. RESULTS For all children comb...

متن کامل

Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?

BACKGROUND Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard, the ongoing deliberation as to whether mercury sphygmomanometers should be replaced with the autom...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Arterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer.

Oscillometric blood pressure devices tend to overestimate systolic blood pressure and underestimate diastolic blood pressure compared with sphygmomanometers. Recent studies indicate that discrepancies in performance between these devices may differ between healthy and diabetic subjects. Arterial stiffness in diabetics could be the underlying factor explaining these differences. We studied diffe...

متن کامل

Skip patterns in DINAMAP-measured blood pressure in 3 epidemiological studies.

Blood pressure measured by the oscillometric, automated device DINAMAP in 3 large population-based studies sponsored by the National Heart, Lung, and Blood Institute (The Atherosclerosis Risk in Communities Study, The Family Heart Study, and the Hypertension Genetic Epidemiology Network Study) were reviewed to determine an apparent skip pattern in the measurement values. Across the 3 studies, 2...

متن کامل