Use of protein-based standards in automated colorimetric determinations of fructosamine in serum.

نویسندگان

  • J R Baker
  • P A Metcalf
  • R N Johnson
  • D Newman
  • P Rietz
چکیده

We have developed an automated colorimetric assay for glycated serum proteins (or fructosamines), measuring the reducing activity of serum in alkaline solution (pH 10.35) at 37 degrees C. The calibrants were prepared from a synthetic fructosamine (1-deoxy-1-morpholinofructose), although secondary standards of glycated bovine albumin were more robust in routine application. Interference was appreciable only with icteric specimens (bilirubin greater than 60 mumol/L), and between-batch imprecision (CV) was less than 2%. The range of fructosamine concentrations measured in 502 healthy (nondiabetic) blood donors was 1.87-2.87 mmol/L. There were no significant (p greater than 0.05) age- or sex-related differences in this population sample. Fructosamine accurately reflected blood glucose control as evidenced by the significant correlation with glucose concentrations in fasting plasma (r = 0.82, p less than 0.001) and with glycated hemoglobin (HbA1c) (r = 0.87, p less than 0.01) in 115 patients with type 2 (non-insulin-dependent) diabetes mellitus. The test is simple and rapid to perform (75 samples per hour) and provides an alternative to HbA1c determinations for monitoring blood glucose control and assessing the effects of changes in diabetes management.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of timing in the fructosamine assay.

The fructosamine assay, based on the measurement of the reducing activity in serum at alkaline pH, provides an index of protein glycation. The reducing activity is expressed in equivalents of 1-deoxy-1-morpholinofructose (DMF) by direct comparison with the activity either of this synthetic compound or with a secondary protein standard calibrated against DMF. This study reports the influence of ...

متن کامل

Assay of serum fructosamine that minimizes standardization and matrix problems: use to assess components of biological variation.

Methodological problems with the assay of fructosamine in serum--standardization, matrix effects, and dependence on buffer pH--have been minimized with a method involving colorimetric assay of each specimen and subsequent re-assay after standard addition of 1-deoxy-1-morpholinofructose. Absorbance at optimum wavelength of 540 nm varies linearly with fructosamine concentration to at least 5.5 mm...

متن کامل

Determination of free haemoglobin in serum by an automated assay using 4-aminophenazone and the Cobas Bio System.

A colorimetric method for the determination of free haemoglobin in human serum is described, using 4-aminophenazone as chromogen, and commercially available haemiglobin cyanide solutions as standards. The reaction system is suitable for manual measurements as well as determinations with a centrifugal analyser (Cobas Bio System). Accuracy, linearity and stability of the procedure is shown. A ref...

متن کامل

Effects of various serum proteins on quantification of fructosamine.

We determined fructosamine concentrations with the CentrifiChem 600 centrifugal analyzer and the Hitachi 737 discrete analyzer. Reference intervals agreed with the most recently published results, and values in fasting patients were significantly correlated with glycated hemoglobin, plasma glucose, albumin, beta- and gamma-globulins, IgG, IgA, IgM, and total protein. Partial correlation analysi...

متن کامل

Automated fructosamine assay with improved accuracy used to quantify nonenzymatic glycation of serum proteins in diabetes mellitus and chronic renal failure.

We optimally solubilized the diformazan that forms during the fructosamine reaction with a nonionic detergent; we then automated the assay. After optimal solubilization of diformazan, we found that serum urate contributed significantly to the color formation in fructosamine reaction. When the error introduced by urate was corrected mathematically by use of an experimental determined factor, the...