Automatic field map generation and off-resonance correction for projection reconstruction imaging.

نویسندگان

  • K S Nayak
  • D G Nishimura
چکیده

A new projection reconstruction technique utilizes the oversampling of low spatial frequencies to estimate and correct for off-resonance effects. Interleaved spokes are acquired at one of two different echo times. From separated early-TE and late-TE raw data, two one-quarter resolution images are reconstructed and a one-quarter resolution field map is computed. Multifrequency reconstruction with all the data is then used to simultaneously correct for off-resonance and compensate for the difference in echo times. Resulting images obtained on phantoms and in vivo demonstrate significantly reduced off-resonance artifact without the acquisition of a separate field map.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast automatic linear off-resonance correction method for spiral imaging.

Field inhomogeneity and susceptibility variations, coupled with a long readout, can result in image blurring in spiral imaging. Many correction methods based on a priori off-resonance information, such as an acquired field map, have been proposed in the literature. Automatic off-resonance correction methods are alternative approaches that estimate a field map from the image data themselves. In ...

متن کامل

Impact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT

Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...

متن کامل

Novel automatic off-resonance correction without field maps in spiral imaging using L1 minimization

Corrected image using the field map (a) (d) The field map created using phase-based correction (c) Novel automatic off-resonance correction without field maps in spiral imaging using L1 minimization Hisamoto Moriguchi, Kohki Yoshikawa, Morio Shimada, Shin-ichi Urayama, Yutaka Imai, Manabu Honda, and Takashi Hanakawa Radiology, Tokai University, Isehara, Kanagawa, Japan, Radiological Sciences, K...

متن کامل

Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of co...

متن کامل

Efficient off-resonance correction for spiral imaging.

A new spiral imaging technique incorporates the acquisition of a field map into imaging interleaves. Variable density spiral trajectories are designed to oversample the central region of k-space, and interleaves are acquired at two different echo times. A field map is extracted from this data and multifrequency reconstruction is used to form an off-resonance corrected image using the entire dat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2000