OCT Study of Mechanical Properties Associated with Trabecular Meshwork and Collector Channel Motion in Human Eyes
نویسندگان
چکیده
We report the use of a high-resolution optical coherence tomography (OCT) imaging platform to identify and quantify pressure-dependent aqueous outflow system (AOS) tissue relationships and to infer mechanical stiffness through examination of tissue properties in ex vivo human eyes. Five enucleated human eyes are included in this study, with each eye prepared with four equal-sized quadrants, each encompassing 90 degrees of the limbal circumference. In radial limbal segments perfusion pressure within Schlemm's canal (SC) is controlled by means of a perfusion cannula inserted into the canal lumen, while the other end of the cannula leads to a reservoir at a height that can control the pressure in the cannula. The OCT system images the sample with a spatial resolution of about 5 μm from the trabecular meshwork (TM) surface. Geometric parameters are quantified from the 2D OCT images acquired from the sample subjected to controlled changes in perfusion pressures; parameters include area and height of the lumen of SC, collector channel entrances (CCE) and intrascleral collector channels (ISCC). We show that 3D OCT imaging permits the identification of 3-D relationships of the SC, CCE and ISCC lumen dimensions. Collagen flaps or leaflets are found at CCE that are attached or hinged at only one end, whilst the flaps are connected to the TM by cylindrical structures spanning SC. Increasing static SC pressures resulted in SC lumen enlargement with corresponding enlargement of the CCE and ISCC lumen. Pressure-dependent SC lumen area and height changes are significant at the 0.01 levels for ANOVA, and at the 0.05 for both polynomial curves and Tukey paired comparisons. Dynamic measurements demonstrate a synchronous increase in SC, CCE and ISCC lumen height in response to pressure changes from 0 to 10, 30 or 50 mm Hg, respectively, and the response time is within the 50-millisecond range. From the measured SC volume and corresponding IOP values, we demonstrate that an elastance curve can be developed to infer the mechanical stiffness of the TM by means of quantifying pressure-dependent SC volume changes over a 2 mm radial region of SC. Our study finds pressure-dependent motion of the TM that corresponds to collagen leaflet configuration motion at CCE; the synchronous tissue motion also corresponds with synchrony of SC and CCE lumen dimension changes.
منابع مشابه
Preferential fluid flow in the human trabecular meshwork near collector channels.
PURPOSE To determine whether preferential pathways exist within the human trabecular meshwork, pigmented and nonpigmented regions adjacent to and between collector channels were examined, and the configuration of the juxtacanalicular tissue (JCT) was analyzed. METHODS Healthy whole human eyes were perfused at 10 or 25 mm Hg with 0.5 mum fluorescent beads. Tissue wedges of pigmented and nonpig...
متن کاملAqueous Humor Levels of Soluble Fas and Fas-ligand in Patients with Primary Open Angle and Pseudoex-foliation Glaucoma
Background: Glaucoma is one of the most common causes of blindness and is usually associated with elevated intraocular pressure. In patients with primary open angle glau-coma the number of trabecular meshwork cells is decreased. Death of the trabecular meshwork cells may be a result of apoptosis. Objective: To investigate the aqueous humor levels of soluble Fas (sFas) and Fas-Ligand (sFasL) in ...
متن کاملAn imaged-based inverse finite element method to determine in-vivo mechanical properties of the human trabecular meshwork.
Aim Previous studies have shown that the trabecular meshwork (TM) is mechanically stiffer in glaucomatous eyes as compared to normal eyes. It is believed that elevated TM stiffness increases resistance to the aqueous humor outflow, producing increased intraocular pressure (IOP). It would be advantageous to measure TM mechanical properties in vivo, as these properties are believed to play an imp...
متن کاملImaging the aqueous humor outflow pathway in human eyes by three-dimensional micro-computed tomography (3D micro-CT).
The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Tradit...
متن کاملHyaluronan in the human trabecular meshwork.
PURPOSE Hyaluronan (HA) is a high-molecular weight glycosaminoglycan that can affect water and solute fluxes in the extracellular matrix. The distribution of HA in the human trabecular meshwork of nonglaucomatous eyes was examined to help understand the potential role of HA in the regulation of aqueous outflow resistance. METHODS Histolocalization of HA was established in situ in the trabecul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016