Immunoaffinity column cleanup with liquid chromatography for determination of aflatoxin M1 in liquid milk: collaborative study.

نویسندگان

  • S Dragacci
  • F Grosso
  • J Gilbert
چکیده

A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aflatoxin M1 in Milk by Immunoaffinity Column Cleanup with Tlc/hplc Determination

During 2002 and 2003, a total of 107 samples of raw, pasteurized and ultrahigh treated temperature (UHT) milk commercialized in the cities of São Paulo and Marília (SP) were analyzed for the presence of aflatoxin M1 (AFM1). AFM1 was detected in 79 (73.8%) of milk samples, ranging from <0.02 to 0.26 μg/L.The samples were analyzed using an immunoaffinity column for cleanup and a thin layer chroma...

متن کامل

Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method

Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...

متن کامل

Determination of Aflatoxin M1 in Pasteurized Liquid and Powdered Milk Products Imported to Iran

Mycotoxins are the secondary metabolites of molds and have adverse effects on humans, animals, and crops, resulting in illnesses and economic losses. Aflatoxin M1 (AFM1) is a hepatocarcinogen found in the milk from animals that have consumed feeds contaminated with aflatoxin B1 (AFB1). Milk is a highly nutritious food and is a source of necessary macro- and micro-nutrients for the growth, devel...

متن کامل

Determination of Aflatoxin M1 in Pasteurized Milk Consumed in Kerman Province

Background & Aims: Aflatoxin M1 (AFM1) is a major metabolite of aflatoxin B1 detected in the milk of mammals that their foods have been contaminated with aflatoxins. Aflatoxins are a group of highly toxic metabolites produced by the common fungi Aspergillus flavus, A. parasiticus. They are among the most potent carcinogens found in foods. Considering its risk to the human health and high consum...

متن کامل

Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxin B1 in cattle feed: collaborative study.

A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone-water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 2  شماره 

صفحات  -

تاریخ انتشار 2001