Volume-associated ambulatory blood pressure patterns in hemodialysis patients.

نویسنده

  • Rajiv Agarwal
چکیده

Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) "signature," a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients randomized, controlled trial. Using 400 ambulatory BP recordings over 8 weeks composed of 35 302 measurements, the trended cosinor model was found to be the best descriptor of BP chronobiology. The trended cosinor model may be described as a pattern of sinusoidal oscillation around a straight line with an upward trend during the interdialytic period that has an intercept at the postdialysis time. Augmented volume removal therapy reduced the intercept systolic BP and increased the rate of rise in systolic BP over the interdialytic interval but had no effect on the systolic BP fluctuation (amplitude). Thus, an elevated intercept and blunted slope pattern characterize the "volume-overload BP pattern" on ambulatory BP monitoring. Similar changes were seen for diastolic BP. Augmented volume removal therapy neither restored dipping nor was associated with a lag phenomenon for either the wake or the sleep systolic BP. Lowering of systolic BP was greater than diastolic BP such that pulse pressure was reduced. An observational cohort of 37 patients followed for 6 months confirmed these findings. Randomized trials are now needed to evaluate the clinical impact of augmented volume removal therapy on hard outcomes, because reduction of pulse pressure with this simple expedient has the potential to improve survival in hemodialysis patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodialysis Volume-Associated Ambulatory Blood Pressure Patterns in Hemodialysis Patients

Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) “signature,” a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients rand...

متن کامل

Arterial stiffness and interdialytic weight gain influence ambulatory blood pressure patterns in hemodialysis patients.

Besides an overall increase in blood pressure, hemodialysis patients have marked disturbance in interdialytic ambulatory blood pressure pattern that is characterized by blunted circadian amplitude and a steady rise in blood pressure between dialysis treatments. The pathophysiology of this abnormal blood pressure profile is poorly understood. We hypothesized that the circadian amplitude, the int...

متن کامل

Comparing the frequency of hypertension determined by peri-dialysis measurement and ABPM in hemodialysis patients.

Controlling blood pressure in hemodialysis patients is crucial but not always easy. The most common blood pressure measurement method is peri-dialysis measurement, but due to interdialytic blood pressure fluctuations, we are unsure if it is the proper way for evaluating blood pressure. Some studies have shown the superiority of 24-h ambulatory blood pressure monitoring over peri-dialysis blood ...

متن کامل

Hemodialysis Blood Pressure and Mortality Among Hemodialysis Patients

Blood pressure measured before and after dialysis does not agree well with those recorded outside the dialysis unit. Whether recordings obtained outside the dialysis unit are of greater prognostic value than blood pressure obtained just before and after dialysis remains incompletely understood. Among 326 patients on long-term hemodialysis, blood pressure was self-measured at home for 1 week, ov...

متن کامل

Relative plasma volume monitoring during hemodialysis AIDS the assessment of dry weight.

Among hemodialysis patients, the assessment of dry weight remains a matter of clinical judgment because tests to assess dry weight have not been validated. The objective of this study was to evaluate and validate relative plasma volume (RPV) monitoring as a marker of dry weight. We performed RPV monitoring using the Crit-Line monitor at baseline and at 8 weeks in 150 patients participating in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hypertension

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2009