The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi

نویسندگان

  • Marriott Nliwasa
  • Peter MacPherson
  • Palesa Chisala
  • Mercy Kamdolozi
  • McEwen Khundi
  • Kruger Kaswaswa
  • Mphatso Mwapasa
  • Chisomo Msefula
  • Hojoon Sohn
  • Clare Flach
  • Elizabeth L. Corbett
چکیده

BACKGROUND Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. OBJECTIVE To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. METHODS Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. RESULTS Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). CONCLUSION The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

Loop-mediated isothermal amplification (RT-LAMP): a new approach for the detection of foot-and-mouth disease virus and its sero-types in Pakistan

Successful disease management requires a rapid and sensitive diagnosis method that can recognize early infection even before the manifestation of its clinical signs. The only available field diagnostic tests for foot-and-mouth disease (FMD) are lateral flow devices, commonly known as chromatographic strips. Low sensitivity and inability to detect FMD virus (FMDV) at the serotype level are limit...

متن کامل

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Clinical profiling and use of loop-mediated isothermal amplification assay for rapid detection of Mycobacterium tuberculosis from sputum.

BACKGROUND Tuberculosis is a global health problem and the situation is worsening with newer incidences of drug resistance and HIV association. Diagnosis of tuberculosis can be done by many methods and test, culture of sputum being the ideal one. Nucleic acid amplification (NAA) assay are more time efficient one, that amplify and detect specific nucleic acid sequences allows rapid, sensitive an...

متن کامل

تشخیص و افتراق سریع فاسیولا هپاتیکا و فاسیولا ژیگانتیکا با استفاده از روش loop-mediated Isothermal Amplification

Background and purpose: Fasciola hepatica and Fasciola gigantica are common liver flukes which affect both human and livestock worldwide. In this study we evaluated the loop-mediated isothermal amplification (LAMP) assay for detection and discrimination of Fasciola species. Materials and methods: Fifty adults of Fasciola worms were isolated from sheep and cattle liver form abattoirs in Mazand...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016