Detection of Iron Overload through Neutron Stimulated Emission Computed Tomography: A Sensitivity Analysis Study

نویسندگان

  • Anuj J. Kapadia
  • Greeshma A. Agasthya
  • Georgia D. Tourassi
  • Carl E. Ravin
چکیده

Neutron stimulated emission computed tomography (NSECT) is being developed as a non-invasive technique to diagnose iron overload in the liver. It uses inelastic scatter interactions between fast neutrons and iron nuclei to quantify localized distributions of iron within the liver. Preliminary studies have demonstrated the feasibility of iron overload detection through NSECT using a Monte-Carlo simulation model in GEANT4. The work described here uses the GEANT4 simulation model to analyze iron-overload detection sensitivity in NSECT. A simulation of a clinical NSECT system was designed in GEANT4. Simulated models were created for human liver phantoms with concentrations of iron varying from 0.5 mg/g to 20 mg/g (wet). Each liver phantom was scanned with 100 million neutron events to generate gamma spectra showing gamma-lines corresponding to iron in the liver. A background spectrum was obtained using a water phantom of equal mass as the liver phantom and was subtracted from each liver spectrum. The height of the gamma line at 847 keV (corresponding to Fe) was used as a measure of the detected iron concentration in each background-corrected spectrum. The variation in detected gamma counts was analyzed and plotted as a function of the liver iron concentration to quantify measurement error. Analysis of the differences between the measured and expected value of iron concentration indicate that NSECT sensitivity for detection of iron in liver tissue may lie in the range of 0.5 mg/g – 1 mg/g, which represents a clinically significant range for iron overload detection in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and Patient Dose in Neutron Stimulated Emission Computed Tomography for Diagnosis of Iron Overload: Simulations in Geant4 Accuracy and Patient Dose in Neutron Stimulated Emission Computed Tomography for Diagnosis of Iron Overload: Simulations in Geant4

ACCURACY AND PATIENT DOSE IN NEUTRON STIMULATED EMISSION COMPUTED TOMOGRAPHY FOR DIAGNOSIS OF IRON OVERLOAD: SIMULATIONS IN GEANT4 by Anuj Jawahar Kapadia Department of Biomedical Engineering Duke University Date:_______________________ Approved: ___________________________ Georgia D. Tourassi, Ph.D., Supervisor ___________________________ Gregg E. Trahey, Ph.D., Supervisor ____________________...

متن کامل

A Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

متن کامل

Noninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI

Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...

متن کامل

The Accuracy of Ultrasonography in Compared with Computed Tomography in Detection of Anterior Mediastinal Neoplasms

Abstract Background The aim of this study was to evaluate sensitivity and specificity of mediastinal sonography, and compared with CT, in detection of anterior mediastinal neoplasms. Materials and Methods The sonography with convex probes (5.0 and 7.5 MHz) was done prospectively for 34 patients (from 2 to 25 years old) with mediastinal mass. The results were compared with the results of ...

متن کامل

DEVELOPMENT AND DESIGN OF A NEAR-FIELD HIGH-ENERGY GAMMA CAMERA FOR USE WITH NEUTRON STIMULATED EMISSION COMPUTED TOMOGRAPHY by

DEVELOPMENT AND DESIGN OF A NEAR-FIELD HIGH-ENERGY GAMMA CAMERA FOR USE WITH NEUTRON STIMULATED EMISSION COMPUTED TOMOGRAPHY by Amy Congdon Sharma Department of Biomedical Engineering Duke University Date: November 14, 2007 Approved: ___________________________ Gregg E. Trahey, Ph.D., Co-Supervisor ___________________________ Georgia D. Tourassi, Ph.D., Co-Supervisor ___________________________...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009