The saccadic spike artifact in MEG
نویسندگان
چکیده
Electro- and magnetoencephalography (EEG/MEG) are the means to investigate the dynamics of neuronal activity non-invasively in the human brain. However, both EEG and MEG are also sensitive to non-neural sources, which can severely complicate the interpretation. The saccadic spike potential (SP) at saccade onset has been identified as a particularly problematic artifact in EEG because it closely resembles synchronous neuronal gamma band activity. While the SP and its confounding effects on EEG have been thoroughly characterized, the corresponding artifact in MEG, the saccadic spike field (SF), has not been investigated. Here we provide a detailed characterization of the SF. We simultaneously recorded MEG, EEG, gaze position and electrooculogram (EOG). We compared the SF in MEG for different saccade sizes and directions and contrasted it with the well-known SP in EEG. Our results reveal a saccade amplitude and direction dependent, lateralized saccadic spike artifact, which was most prominent in the gamma frequency range. The SF was strongest at frontal and temporal sensors but unlike the SP in EEG did not contaminate parietal sensors. Furthermore, we observed that the source configurations of the SF were comparable for regular and miniature saccades. Using distributed source analysis we identified the sources of the SF in the extraocular muscles. In summary, our results show that the SF in MEG closely resembles neuronal activity in frontal and temporal sensors. Our detailed characterization of the SF constitutes a solid basis for assessing possible saccadic spike related contamination in MEG experiments.
منابع مشابه
Toward a definition of MEG spike: Parametric description of spikes recorded simultaneously by MEG and depth electrodes
There is not yet a formal definition of magnetoencephalography (MEG) spike. This study provides a parametric description and definition of clear-cut MEG spikes recorded simultaneously by MEG and depth electrodes (iEEG). A total number of 367 simultaneous MEG/iEEG spikes were selected for analysis. Distribution of morphologic spike parameters and detailed quantitative analysis of the basic morph...
متن کاملInterpretation of MEG spike source localization in frontal lobe epilepsy with multiple independent spike foci
Magnetic source imaging using a whole-head MEG system provides a more accurate localization of epileptic focus than other routinely used noninvasive methods such as scalp video EEG and magnetic resonance imaging (MRI) [1-3]. However, MEG source localization, as estimated by the single dipole and spherical model, may not fully describe an epileptic region that includes extensive or multiple epil...
متن کاملWhere left becomes right: a magnetoencephalographic study of sensorimotor transformation for antisaccades.
To perform a saccadic response to a visual stimulus, a 'sensorimotor transformation' is required (i.e., transforming stimulus location into a motor command). Where in the brain is this accomplished? While previous monkey neurophysiology and human fMRI studies examined either parietal cortex or frontal eye field, we studied both of these regions simultaneously using magnetoencephalography (MEG)....
متن کاملMagnetoencephalography Interictal Spike Clustering in Relation with Surgical Outcome of Cortical Dysplasia
OBJECTIVE The aim of this study was to devise an objective clustering method for magnetoencephalography (MEG) interictal spike sources, and to identify the prognostic value of the new clustering method in adult epilepsy patients with cortical dysplasia (CD). METHODS We retrospectively analyzed 25 adult patients with histologically proven CD, who underwent MEG examination and surgical resectio...
متن کاملCombining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data
Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 59 شماره
صفحات -
تاریخ انتشار 2012