No benefit of a proximal stem centralizer in cementing of a femoral prosthesis in human cadavers

نویسندگان

  • Juozas Petruskevicius
  • Thomas Lind-Hansen
  • Ramune Aleksyniene
  • Jens R Nyengaard
  • Poul T Nielsen
  • Kjeld Søballe
چکیده

BACKGROUND AND PURPOSE A proximal stem centralizer may be beneficial regarding cementing pressures, cement penetration, and stem alignment. We measured these parameters when cementing a mat-surfaced femoral component with and without the use of a proximal stem centralizer. MATERIAL AND METHODS 8 femoral prostheses with proximal centralizers and 8 femoral prostheses without proximal centralizers were cemented according to third-generation cementing technique in 8 pairs of embalmed cadaveric femora. We recorded intramedullary pressures (peak levels, the area under the pressure curves and mean pressure) with 6 pressure transducers during stem cementation. Computer tomographic scanning of specimens was performed to evaluate stem alignment after surgery. Thickness of the cement mantle, cement penetration, and stem centralization at the metaphyseal part of the femur were measured on cross sections using stereology. RESULTS There were no statistically significant differences in measured pressure and cement penetration values between the groups. There was similar cement distribution around the stems; however, in using a proximal centralizer, the cement mantle tended to be thinner laterally. Moreover, we found a larger variation in stem alignment on lateral projection in the proximal centralizer group. INTERPRETATION No benefits regarding intramedullary pressures and cement penetration were obtained from cementation of a straight stem with a proximal stem centralizer. However, there was an increased risk of inferior stem positioning in the reamed medullary cavity using the centralizing device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of caulking gun and standard cement gun using for femoral cementation.

BACKGROUND Currently the standard femoral cementing technique requires cement injection gun to deliver bone cement into the femoral canal. The standard cement gun is expensive and must be imported. There is no previous study about the use of a household caulking gun for femoral cementation. OBJECTIVE To compare the radiographic quality of cementing technique in proximal femur between using st...

متن کامل

Femoral Components: The French Paradox

It has become generally accepted that the cement surrounding a proximal femoral implant should be not less than 2 mm thick and that it should be complete i.e. without any ‘windows’ in the mantle. The widely used Barrack grading for cementing included no comment on the thickness of the cement mantle on its introduction in 1992 [1]. The following year the ‘A’ grade was qualified by the addition o...

متن کامل

Effect of a distal centralizer on the positioning of an anatomical stem.

Femoral stem centralizers were originally designed for double tapered, straight stems. In a slightly modified configuration, the PMMA centralizer is plugged in a hole in the tip of the ABG II femoral prosthesis. The purpose of this study was to determine the effect of the centralizer on the position of the anatomical ABG II stem. Thirty-nine cemented ABG II stems with a centralizer were compare...

متن کامل

نتایج درمان تومور سلول ژانت استخوان‌های بلند با استفاده از روش ترکیبی کرایوسرجری، کورتاژ و سیمان گذاری بیمارستان امام ،83-1378

Background: In this study we evaluated the treatment of giant cell tumor (GCT) of long bones using cryosurgery combined with curettage and polymethylmetacrylate (PMMA) cementing.Material and methods: From January 1999 to December 2004, twenty patients (mean age at the time of surgery 29.2 years) 13 females and 7 males were included in the study. Cortical disruption were presented in 7 patients ...

متن کامل

A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?

Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011