Simultaneous acquisition of image and navigator slices using CAIPIRINHA

نویسندگان

  • Z. Celicanin
  • F. Preiswerk
  • P. Arnold
  • P. Cattin
  • K. Scheffler
  • F. Santini
چکیده

Introduction Respiratory organ motion is a complicating factor in many treatments. Especially for dynamic dose delivery such as in tumor therapy, exact knowledge of organ motion and its influence on the dose distribution is crucial. Siebenthal et al [1] recently purposed a novel respiratory correlated MR imaging method that acquires a full 2D sagittal navigator image instead of the commonly used one-dimensional diaphragm navigator. This method allows for tracking vascular structures during complete breathing cycles with minimal out-of-plane motion. The 4D-MRI (three dimensional and one temporal dimension) model of organ motion requires rapid acquisition of 2D images. It also requires high contrast between liver tissue and vessels, in contrast to conventional (and less precise) methods that only detect the diaphragm position. High vessel-tissue contrast is generated with balanced Steady State Free Precession (bSSFP) sequences giving bright vessel signal enhancement. In the original method, image and navigator slices were acquired interleaved. Since the navigator image is used to estimate the exact position and shape of organ, a time lag between image and navigator could lead to discrepancy in images and even to building of incorrect models. In this paper, we describe a new approach to image and navigator acquisition based on multislice Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA) [2], which allows a true simultaneous acquisition with consequent decrease of lag and increase of temporal resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

PURPOSE Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging method is proposed for truly simultaneous high temporal resolution acquisition. ...

متن کامل

Accelerated Simultaneous Multi-slice Cardiac Cine Imaging Using a Combination of CAIPIRINHA and Compressed Sensing

images of the two simultaneously excited slices. Displayed are (a) the conventional reconstruction of the CAIPIRINHA acquisition using GRAPPA and (b) the reconstruction of the incoherently undersampled CAIPIRINHA acquisition using the proposed combination of Compressed Sensing and GRAPPA. (c) Difference between a) and b) magnified by a factor of 10. Accelerated Simultaneous Multi-slice Cardiac ...

متن کامل

CAIPIRINHA accelerated simultaneous multi-slice TrueFISP real-time imaging

Introduction: CAIPIRINHA multi-slice imaging offers the possibility to acquire several imaging slices simultaneously while maintaining the image quality (1), allowing a high acceleration of the imaging procedure. By providing the individual slices with different RF-phase cycles, the simultaneously excited slices are shifted with respect to each other in the FOV, facilitating the separation of t...

متن کامل

Myocardial perfusion imaging using CAIPIRINHA accelerated multi-slice saturation recovery TrueFISP

Introduction: Saturation recovery (SR) prepared TrueFISP sequences are widely in use for myocardial perfusion imaging because of a high intrinsic signal-to-noise ratio (SNR). Since the image acquisition is limited by the heart cycle, a complete coverage of the heart with consecutively acquired slices is difficult. Parallel imaging techniques are required significantly reducing the acquisition t...

متن کامل

Improving diffusion MRI using simultaneous multi-slice echo planar imaging

In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010